CVE-2021-29242 1 Codesys 22 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 19 more 2024-11-21 7.5 HIGH 7.3 HIGH
CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.
CVE-2021-29241 1 Codesys 11 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 8 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).
CVE-2019-9013 1 Codesys 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more 2024-11-21 5.8 MEDIUM 8.8 HIGH
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.
CVE-2019-9012 1 Codesys 10 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 7 more 2024-11-21 7.8 HIGH 7.5 HIGH
An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.
CVE-2019-9010 1 Codesys 10 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 7 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.
CVE-2018-20026 1 Codesys 18 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 15 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
CVE-2018-20025 1 Codesys 15 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 12 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.
CVE-2018-10612 1 Codesys 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.