Filtered by vendor Tenda
Subscribe
Total
802 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-45505 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the cmdinput parameter at /goform/exeCommand. | |||||
CVE-2022-45640 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda Tenda AC6V1.0 V15.03.05.19 is affected by buffer overflow. Causes a denial of service (local). | |||||
CVE-2022-45512 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter. | |||||
CVE-2022-45520 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/qossetting. | |||||
CVE-2022-46532 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceMac parameter at /goform/addWifiMacFilter. | |||||
CVE-2022-45504 | 1 Tenda | 2 W6-s, W6-s Firmware | 2024-02-28 | N/A | 7.5 HIGH |
An issue in the component tpi_systool_handle(0) (/goform/SysToolRestoreSet) of Tenda W6-S v1.0.0.4(510) allows unauthenticated attackers to arbitrarily reboot the device. | |||||
CVE-2022-46551 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the time parameter at /goform/saveParentControlInfo. | |||||
CVE-2022-45510 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the mit_ssid_index parameter at /goform/AdvSetWrlsafeset. | |||||
CVE-2022-46540 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/addressNat. | |||||
CVE-2022-47123 | 1 Tenda | 2 A15, A15 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey3 parameter at /goform/WifiBasicSet. | |||||
CVE-2022-45501 | 1 Tenda | 2 W6-s, W6-s Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the wl_radio parameter at /goform/wifiSSIDset. | |||||
CVE-2022-46534 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the speed_dir parameter at /goform/SetSpeedWan. | |||||
CVE-2022-47122 | 1 Tenda | 2 A15, A15 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd_5g parameter at /goform/WifiBasicSet. | |||||
CVE-2022-46544 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the cmdinput parameter at /goform/exeCommand. | |||||
CVE-2023-24164 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318. | |||||
CVE-2022-45508 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the new_account parameter at /goform/editUserName. | |||||
CVE-2023-25233 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2024-02-28 | N/A | 9.8 CRITICAL |
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface. | |||||
CVE-2022-46549 | 1 Tenda | 2 F1203, F1203 Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/saveParentControlInfo. | |||||
CVE-2022-45667 | 1 Tenda | 2 I22, I22 Firmware | 2024-02-28 | N/A | 6.5 MEDIUM |
Tenda i22 V1.0.0.3(4687) is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolRestoreSet. | |||||
CVE-2022-45509 | 1 Tenda | 2 W30e, W30e Firmware | 2024-02-28 | N/A | 7.5 HIGH |
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName. |