Vulnerabilities (CVE)

Filtered by vendor Ui Subscribe
Total 81 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-1458 1 Ui 2 Edgerouter X, Edgerouter X Firmware 2024-11-21 N/A 7.2 HIGH
A vulnerability has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6 and classified as critical. Affected by this vulnerability is an unknown functionality of the component OSPF Handler. The manipulation of the argument area leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The associated identifier of this vulnerability is VDB-223303. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.
CVE-2023-1457 1 Ui 2 Edgerouter X, Edgerouter X Firmware 2024-11-21 N/A 7.2 HIGH
A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. Affected is an unknown function of the component Static Routing Configuration Handler. The manipulation of the argument next-hop-interface leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. VDB-223302 is the identifier assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.
CVE-2023-1456 1 Ui 2 Edgerouter X, Edgerouter X Firmware 2024-11-21 N/A 7.2 HIGH
A vulnerability, which was classified as critical, has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. This issue affects some unknown processing of the component NAT Configuration Handler. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier VDB-223301 was assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.
CVE-2022-44565 1 Ui 12 Airfiber 60, Airfiber 60-hd, Airfiber 60-hd Firmware and 9 more 2024-11-21 N/A 5.3 MEDIUM
An improper access validation vulnerability exists in airMAX AC <8.7.11, airFiber 60/LR <2.6.2, airFiber 60 XG/HD <v1.0.0 and airFiber GBE <1.4.1 that allows a malicious actor to retrieve status and usage data from the UISP device.
CVE-2022-43553 1 Ui 2 Edgemax Edgerouter, Edgemax Edgerouter Firmware 2024-11-21 N/A 8.8 HIGH
A remote code execution vulnerability in EdgeRouters (Version 2.0.9-hotfix.4 and earlier) allows a malicious actor with an operator account to run arbitrary administrator commands.This vulnerability is fixed in Version 2.0.9-hotfix.5 and later.
CVE-2022-35257 1 Ui 1 Desktop 2024-11-21 N/A 7.8 HIGH
A local privilege escalation vulnerability in UI Desktop for Windows (Version 0.55.1.2 and earlier) allows a malicious actor with local access to a Windows device with UI Desktop to run arbitrary commands as SYSTEM.
CVE-2022-22570 1 Ui 2 Ua Lite, Ua Lite Firmware 2024-11-21 7.5 HIGH 10.0 CRITICAL
A buffer overflow vulnerability found in the UniFi Door Access Reader Lite’s (UA Lite) firmware (Version 3.8.28.24 and earlier) allows a malicious actor who has gained access to a network to control all connected UA devices. This vulnerability is fixed in Version 3.8.31.13 and later.
CVE-2021-44530 1 Ui 1 Unifi Network Controller 2024-11-21 7.5 HIGH 9.8 CRITICAL
An injection vulnerability exists in a third-party library used in UniFi Network Version 6.5.53 and earlier (Log4J CVE-2021-44228) allows a malicious actor to control the application.
CVE-2021-44527 1 Ui 1 Unifi Switch Firmware 2024-11-21 6.1 MEDIUM 6.5 MEDIUM
A vulnerability found in UniFi Switch firmware Version 5.43.35 and earlier allows a malicious actor who has already gained access to the network to perform a Deny of Service (DoS) attack on the affected switch.This vulnerability is fixed in UniFi Switch firmware 5.76.6 and later.
CVE-2021-33820 1 Ui 2 Camera G3 Flex, Camera G3 Flex Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
An issue was discovered in UniFi Protect G3 FLEX Camera Version UVC.v4.30.0.67.Attacker could send a huge amount of TCP SYN packet to make web service's resource exhausted. Then the web server is denial-of-service.
CVE-2021-33818 1 Ui 2 Camera G3 Flex, Camera G3 Flex Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
An issue was discovered in UniFi Protect G3 FLEX Camera Version UVC.v4.30.0.67. Attackers can use slowhttptest tool to send incomplete HTTP request, which could make server keep waiting for the packet to finish the connection, until its resource exhausted. Then the web server is denial-of-service.
CVE-2021-22957 1 Ui 1 Unifi Protect 2024-11-21 6.8 MEDIUM 8.8 HIGH
A Cross-Origin Resource Sharing (CORS) vulnerability found in UniFi Protect application Version 1.19.2 and earlier allows a malicious actor who has convinced a privileged user to access a URL with malicious code to take over said user’s account.This vulnerability is fixed in UniFi Protect application Version 1.20.0 and later.
CVE-2021-22952 1 Ui 1 Unifi Talk 2024-11-21 6.5 MEDIUM 8.8 HIGH
A vulnerability found in UniFi Talk application V1.12.3 and earlier permits a malicious actor who has already gained access to a network to subsequently control Talk device(s) assigned to said network if they are not yet adopted. This vulnerability is fixed in UniFi Talk application V1.12.5 and later.
CVE-2021-22944 1 Ui 1 Unifi Protect 2024-11-21 7.7 HIGH 8.0 HIGH
A vulnerability found in UniFi Protect application V1.18.1 and earlier allows a malicious actor with a view-only role and network access to gain the same privileges as the owner of the UniFi Protect application. This vulnerability is fixed in UniFi Protect application V1.19.0 and later.
CVE-2021-22943 1 Ui 1 Unifi Protect 2024-11-21 8.3 HIGH 9.6 CRITICAL
A vulnerability found in UniFi Protect application V1.18.1 and earlier permits a malicious actor who has already gained access to a network to subsequently control the Protect camera(s) assigned to said network. This vulnerability is fixed in UniFi Protect application V1.19.0 and later.
CVE-2021-22909 1 Ui 2 Edgemax Edgerouter, Edgemax Edgerouter Firmware 2024-11-21 7.6 HIGH 7.5 HIGH
A vulnerability found in EdgeMAX EdgeRouter V2.0.9 and earlier could allow a malicious actor to execute a man-in-the-middle (MitM) attack during a firmware update. This vulnerability is fixed in EdgeMAX EdgeRouter V2.0.9-hotfix.1 and later.
CVE-2021-22882 1 Ui 4 Unifi Cloud Key Plus, Unifi Dream Machine Pro, Unifi Network Video Recorder and 1 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
UniFi Protect before v1.17.1 allows an attacker to use spoofed cameras to perform a denial-of-service attack that may cause the UniFi Protect controller to crash.
CVE-2020-8282 1 Ui 4 Edgemax Edgepower 24v, Edgemax Edgepower 24v Firmware, Edgemax Edgepower 54v and 1 more 2024-11-21 6.8 MEDIUM 8.8 HIGH
A security issue was found in EdgePower 24V/54V firmware v1.7.0 and earlier where, due to missing CSRF protections, an attacker would have been able to perform unauthorized remote code execution.
CVE-2020-8267 1 Ui 1 Unifi Protect Firmware 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
A security issue was found in UniFi Protect controller v1.14.10 and earlier.The authentication in the UniFi Protect controller API was using “x-token” improperly, allowing attackers to use the API to send authenticated messages without a valid token.This vulnerability was fixed in UniFi Protect v1.14.11 and newer.This issue does not impact UniFi Cloud Key Gen 2 plus.This issue does not impact UDM-Pro customers with UniFi Protect stopped.Affected Products:UDM-Pro firmware 1.7.2 and earlier.UNVR firmware 1.3.12 and earlier.Mitigation:Update UniFi Protect to v1.14.11 or newer version; the UniFi Protect controller can be updated through your UniFi OS settings.Alternatively, you can update UNVR and UDM-Pro to:- UNVR firmware to 1.3.15 or newer.- UDM-Pro firmware to 1.8.0 or newer.
CVE-2020-8234 1 Ui 12 Edgemax Firmware, Ep-s16, Es-12f and 9 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
A vulnerability exists in The EdgeMax EdgeSwitch firmware <v1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection.