CVE-2022-0010 1 Abb 5 Platform Engineering Tools, Qcs 800xa, Qcs 800xa Firmware and 2 more 2024-02-28 N/A 5.5 MEDIUM
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
CVE-2022-4126 4 Abb, Apple, Linux and 1 more 4 Rccmd, Macos, Linux Kernel and 1 more 2024-02-28 N/A 9.8 CRITICAL
Use of Default Password vulnerability in ABB RCCMD on Windows, Linux, MacOS allows Try Common or Default Usernames and Passwords.This issue affects RCCMD: before 4.40 230207.
CVE-2023-0863 1 Abb 16 Terra Ac Wallbox 80a, Terra Ac Wallbox 80a Firmware, Terra Ac Wallbox Ce Juno and 13 more 2024-02-28 N/A 8.8 HIGH
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
CVE-2023-2625 1 Abb 2 Txpert Hub Coretec 4, Txpert Hub Coretec 4 Firmware 2024-02-28 N/A 8.0 HIGH
A vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment as the CoreTec 4, having any level of access VIEWER to ADMIN. To exploit the vulnerability the attacker can inject shell commands through a particular field of the web user interface that will be executed by the system.
CVE-2022-3192 1 Abb 30 Ac500 Cpu Firmware, Pm5630-2eth, Pm5650-2eth and 27 more 2024-02-28 N/A 5.3 MEDIUM
Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.
CVE-2023-0636 1 Abb 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more 2024-02-28 N/A 9.8 CRITICAL
Improper Input Validation vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Command Injection.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.0; NEXUS Series: from 3.0;0 before 3.07.0; MATRIX Series: from 3.0;0 before 3.07.1.
CVE-2023-0864 1 Abb 16 Terra Ac Wallbox 80a, Terra Ac Wallbox 80a Firmware, Terra Ac Wallbox Ce Juno and 13 more 2024-02-28 N/A 4.3 MEDIUM
Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
CVE-2022-26080 1 Abb 14 H5692448 G104, H5692448 G104 Firmware, H5692448 G224l and 11 more 2024-02-28 N/A 4.3 MEDIUM
Use of Insufficiently Random Values vulnerability in ABB Pulsar Plus System Controller NE843_S, ABB Infinity DC Power Plant.This issue affects Pulsar Plus System Controller NE843_S : comcode 150042936; Infinity DC Power Plant: H5692448 G104 G842 G224L G630-4 G451C(2) G461(2) – comcode 150047415.
CVE-2022-3573 2 Abb, Gitlab 2 Drive Composer, Gitlab 2024-02-28 N/A 5.4 MEDIUM
An issue has been discovered in GitLab CE/EE affecting all versions starting from 15.4 before 15.5.7, all versions starting from 15.6 before 15.6.4, all versions starting from 15.7 before 15.7.2. Due to the improper filtering of query parameters in the wiki changes page, an attacker can execute arbitrary JavaScript on the self-hosted instances running without strict CSP.
CVE-2022-1607 1 Abb 2 Infinity Dc Power Plant, Ne843 S 2024-02-28 N/A 8.8 HIGH
Cross-Site Request Forgery (CSRF) vulnerability in ABB Pulsar Plus System Controller NE843_S, ABB Infinity DC Power Plant allows Cross Site Request Forgery.This issue affects Pulsar Plus System Controller NE843_S : comcode 150042936; Infinity DC Power Plant: H5692448 G104 G842 G224L G630-4 G451C(2) G461(2) – comcode 150047415.
CVE-2023-0228 1 Abb 1 Symphony Plus S\+ Operations 2024-02-28 N/A 8.8 HIGH
Improper Authentication vulnerability in ABB Symphony Plus S+ Operations.This issue affects Symphony Plus S+ Operations: from 2.X through 2.1 SP2, 2.2, from 3.X through 3.3 SP1, 3.3 SP2.
CVE-2021-22283 1 Abb 38 Evd4, Evd4 Firmware, Rec615 and 35 more 2024-02-28 N/A 5.5 MEDIUM
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
CVE-2022-34837 1 Abb 1 Zenon 2024-02-28 N/A 6.1 MEDIUM
Storing Passwords in a Recoverable Format vulnerability in ABB Zenon 8.20 allows an attacker who successfully exploit the vulnerability may add more network clients that may monitor various activities of the Zenon.
CVE-2022-0902 1 Abb 14 Rmc-100, Rmc-100-lite, Rmc-100-lite Firmware and 11 more 2024-02-28 N/A 9.8 CRITICAL
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
CVE-2022-34838 1 Abb 1 Zenon 2024-02-28 N/A 8.4 HIGH
Storing Passwords in a Recoverable Format vulnerability in ABB Zenon 8.20 allows an attacker who successfully exploit the vulnerability may add or alter data points and corresponding attributes. Once such engineering data is used the data visualization will be altered for the end user.
CVE-2022-34836 1 Abb 1 Zenon 2024-02-28 N/A 8.2 HIGH
Relative Path Traversal vulnerability in ABB Zenon 8.20 allows the user to access files on the Zenon system and user also can add own log messages and e.g., flood the log entries. An attacker who successfully exploit the vulnerability could access the Zenon runtime activities such as the start and stop of various activity and the last error code etc.
CVE-2022-28702 1 Abb 1 E-design 2024-02-28 4.9 MEDIUM 5.5 MEDIUM
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
CVE-2022-28613 2 Abb, Hitachienergy 3 Rtu500 Firmware, Rtu500, Rtu500 Firmware 2024-02-28 7.8 HIGH 7.5 HIGH
A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an ATTACKER to reboot the device by sending a special crafted message. This issue affects: Hitachi Energy RTU500 series CMU Firmware 12.0.*; 12.2.*; 12.4.*; 12.6.*; 12.7.*; 13.2.*.
CVE-2021-22277 1 Abb 4 800xa, Base Software, Compact Product Suite and 1 more 2024-02-28 7.8 HIGH 7.5 HIGH
Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
CVE-2022-29483 1 Abb 1 E-design 2024-02-28 7.2 HIGH 7.8 HIGH
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.