Total
29 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-22515 | 1 Codesys | 18 Control For Beaglebone Sl, Control For Beckhoff Cx9020, Control For Empc-a\/imx6 Sl and 15 more | 2024-11-21 | 4.9 MEDIUM | 8.1 HIGH |
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products. | |||||
CVE-2022-22514 | 1 Codesys | 20 Control For Beaglebone Sl, Control For Beckhoff Cx9020, Control For Empc-a\/imx6 Sl and 17 more | 2024-11-21 | 4.9 MEDIUM | 7.1 HIGH |
An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash. | |||||
CVE-2022-22513 | 1 Codesys | 20 Control For Beaglebone Sl, Control For Beckhoff Cx9020, Control For Empc-a\/imx6 Sl and 17 more | 2024-11-21 | 3.5 LOW | 6.5 MEDIUM |
An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash. | |||||
CVE-2021-36763 | 1 Codesys | 7 Control, Control Rte, Control Runtime System Toolkit and 4 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. | |||||
CVE-2021-33485 | 1 Codesys | 7 Control, Control Rte, Control Runtime System Toolkit and 4 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. | |||||
CVE-2019-9013 | 1 Codesys | 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more | 2024-11-21 | 5.8 MEDIUM | 8.8 HIGH |
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3. | |||||
CVE-2018-20026 | 1 Codesys | 18 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 15 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0. | |||||
CVE-2018-20025 | 1 Codesys | 15 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 12 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0. | |||||
CVE-2018-10612 | 1 Codesys | 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. |