CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-7506 | 1 Moxa | 1 Mxview | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
The private key of the web server in Moxa MXview versions 2.8 and prior is able to be read and accessed via an HTTP GET request, which may allow a remote attacker to decrypt encrypted information. | |||||
CVE-2017-14437 | 1 Moxa | 2 Edr-810, Edr-810 Firmware | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An exploitable denial of service vulnerability exists in the web server functionality of Moxa EDR-810 V4.1 build 17030317. A specially crafted HTTP URI can cause a null pointer dereference resulting in denial of service. An attacker can send a GET request to "/MOXA\_LOG.ini" without a cookie header to trigger this vulnerability. | |||||
CVE-2018-5455 | 1 Moxa | 8 Oncell G3110-hspa, Oncell G3110-hspa-t, Oncell G3110-hspa-t Firmware and 5 more | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions. | |||||
CVE-2017-12124 | 1 Moxa | 2 Edr-810, Edr-810 Firmware | 2024-02-28 | 4.3 MEDIUM | 6.5 MEDIUM |
An exploitable denial of service vulnerability exists in the web server functionality of Moxa EDR-810 V4.1 build 17030317. A specially crafted HTTP URI can cause a null pointer dereference resulting in the web server crashing. An attacker can send a crafted URI to trigger this vulnerability. | |||||
CVE-2017-14028 | 1 Moxa | 6 Nport 5110, Nport 5110 Firmware, Nport 5130 and 3 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
A Resource Exhaustion issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to exhaust memory resources by sending a large amount of TCP SYN packets. | |||||
CVE-2017-13701 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2024-02-28 | 5.0 MEDIUM | 9.8 CRITICAL |
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method. | |||||
CVE-2017-14030 | 1 Moxa | 1 Mxview | 2024-02-28 | 4.6 MEDIUM | 7.8 HIGH |
An issue was discovered in Moxa MXview v2.8 and prior. The unquoted service path escalation vulnerability could allow an authorized user with file access to escalate privileges by inserting arbitrary code into the unquoted service path. | |||||
CVE-2017-13699 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it. | |||||
CVE-2017-13702 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2024-02-28 | 5.0 MEDIUM | 5.3 MEDIUM |
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused. | |||||
CVE-2017-7915 | 1 Moxa | 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more | 2024-02-28 | 7.5 HIGH | 9.8 CRITICAL |
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication. | |||||
CVE-2017-7917 | 1 Moxa | 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more | 2024-02-28 | 6.8 MEDIUM | 8.8 HIGH |
A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device. | |||||
CVE-2017-16719 | 1 Moxa | 6 Nport 5110, Nport 5110 Firmware, Nport 5130 and 3 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An Injection issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to inject packets that could potentially disrupt the availability of the device. | |||||
CVE-2017-13700 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2024-02-28 | 3.5 LOW | 4.8 MEDIUM |
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface. | |||||
CVE-2017-16727 | 1 Moxa | 4 Nport W2150a, Nport W2150a Firmware, Nport W2250a and 1 more | 2024-02-28 | 6.4 MEDIUM | 9.1 CRITICAL |
A Credentials Management issue was discovered in Moxa NPort W2150A versions prior to 1.11, and NPort W2250A versions prior to 1.11. The default password is empty on the device. An unauthorized user can access the device without a password. An unauthorized user has the ability to completely compromise the confidentiality and integrity of the wireless traffic. | |||||
CVE-2017-13698 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded. | |||||
CVE-2017-16715 | 1 Moxa | 6 Nport 5110, Nport 5110 Firmware, Nport 5130 and 3 more | 2024-02-28 | 5.0 MEDIUM | 7.5 HIGH |
An Information Exposure issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to exploit a flaw in the handling of Ethernet frame padding that may allow for information exposure. | |||||
CVE-2017-7913 | 1 Moxa | 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more | 2024-02-28 | 5.0 MEDIUM | 9.8 CRITICAL |
A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext. | |||||
CVE-2017-13703 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2024-02-28 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur. | |||||
CVE-2016-8372 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2024-02-28 | 4.3 MEDIUM | 8.1 HIGH |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure. | |||||
CVE-2016-8350 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2024-02-28 | 6.8 MEDIUM | 6.3 MEDIUM |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY). |