CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-24562 2024-03-14 N/A 5.4 MEDIUM
vantage6-UI is the official user interface for the vantage6 server. In affected versions a number of security headers are not set. This issue has been addressed in commit `68dfa6614` which is expected to be included in future releases. Users are advised to upgrade when a new release is made. While an upgrade path is not available users may modify the docker image build to insert the headers into nginx.
CVE-2023-41319 1 Ethyca 1 Fides 2024-02-28 N/A 7.2 HIGH
Fides is an open-source privacy engineering platform for managing the fulfillment of data privacy requests in a runtime environment, and the enforcement of privacy regulations in code. The Fides webserver API allows custom integrations to be uploaded as a ZIP file. This ZIP file must contain YAML files, but Fides can be configured to also accept the inclusion of custom Python code in it. The custom code is executed in a restricted, sandboxed environment, but the sandbox can be bypassed to execute any arbitrary code. The vulnerability allows the execution of arbitrary code on the target system within the context of the webserver python process owner on the webserver container, which by default is `root`, and leverage that access to attack underlying infrastructure and integrated systems. This vulnerability affects Fides versions `2.11.0` through `2.19.0`. Exploitation is limited to API clients with the `CONNECTOR_TEMPLATE_REGISTER` authorization scope. In the Fides Admin UI this scope is restricted to highly privileged users, specifically root users and users with the owner role. Exploitation is only possible if the security configuration parameter `allow_custom_connector_functions` is enabled by the user deploying the Fides webserver container, either in `fides.toml` or by setting the env var `FIDES__SECURITY__ALLOW_CUSTOM_CONNECTOR_FUNCTIONS=True`. By default this configuration parameter is disabled. The vulnerability has been patched in Fides version `2.19.0`. Users are advised to upgrade to this version or later to secure their systems against this threat. Users unable to upgrade should ensure that `allow_custom_connector_functions` in `fides.toml` and the `FIDES__SECURITY__ALLOW_CUSTOM_CONNECTOR_FUNCTIONS` are both either unset or explicit set to `False`.
CVE-2022-39266 1 Isolated-vm Project 1 Isolated-vm 2024-02-28 N/A 9.8 CRITICAL
isolated-vm is a library for nodejs which gives the user access to v8's Isolate interface. In versions 4.3.6 and prior, if the untrusted v8 cached data is passed to the API through CachedDataOptions, attackers can bypass the sandbox and run arbitrary code in the nodejs process. Version 4.3.7 changes the documentation to warn users that they should not accept `cachedData` payloads from a user.
CVE-2022-22152 1 Juniper 1 Contrail Service Orchestration 2024-02-28 4.0 MEDIUM 6.5 MEDIUM
A Protection Mechanism Failure vulnerability in the REST API of Juniper Networks Contrail Service Orchestration allows one tenant on the system to view confidential configuration details of another tenant on the same system. By utilizing the REST API, one tenant is able to obtain information on another tenant's firewall configuration and access control policies, as well as other sensitive information, exposing the tenant to reduced defense against malicious attacks or exploitation via additional undetermined vulnerabilities. This issue affects Juniper Networks Contrail Service Orchestration versions prior to 6.1.0 Patch 3.
CVE-2021-32835 1 Eclipse 1 Keti 2024-02-28 6.5 MEDIUM 9.9 CRITICAL
Eclipse Keti is a service that was designed to protect RESTfuls API using Attribute Based Access Control (ABAC). In Keti a sandbox escape vulnerability may lead to post-authentication Remote Code execution. This vulnerability is known to exist in the latest commit at the time of writing this CVE (commit a1c8dbe). For more details see the referenced GHSL-2021-063.
CVE-2021-27245 1 Tp-link 2 Archer A7, Archer A7 Firmware 2024-02-28 9.3 HIGH 8.1 HIGH
This vulnerability allows a firewall bypass on affected installations of TP-Link Archer A7 prior to Archer C7(US)_V5_210125 and Archer A7(US)_V5_200220 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of IPv6 connections. The issue results from the lack of proper filtering of IPv6 SSH connections. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-12309.
CVE-2021-1517 1 Cisco 2 Webex Meetings Online, Webex Meetings Server 2024-02-28 4.0 MEDIUM 4.3 MEDIUM
A vulnerability in the multimedia viewer feature of Cisco Webex Meetings and Cisco Webex Meetings Server could allow an authenticated, remote attacker to bypass security protections. This vulnerability is due to unsafe handling of shared content within the multimedia viewer feature. An attacker could exploit this vulnerability by sharing a file through the multimedia viewer feature. A successful exploit could allow the attacker to bypass security protections and prevent warning dialogs from appearing before files are offered to other users.
CVE-2020-15215 1 Electronjs 1 Electron 2024-02-28 6.8 MEDIUM 5.6 MEDIUM
Electron before versions 11.0.0-beta.6, 10.1.2, 9.3.1 or 8.5.2 is vulnerable to a context isolation bypass. Apps using both `contextIsolation` and `sandbox: true` are affected. Apps using both `contextIsolation` and `nodeIntegrationInSubFrames: true` are affected. This is a context isolation bypass, meaning that code running in the main world context in the renderer can reach into the isolated Electron context and perform privileged actions.
CVE-2020-16198 1 Philips 1 Clinical Collaboration Platform 2024-02-28 5.8 MEDIUM 6.3 MEDIUM
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. When an attacker claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2019-13924 1 Siemens 16 Scalance X-200irt, Scalance X-200irt Firmware, Scalance X-300 and 13 more 2024-02-28 4.3 MEDIUM 5.4 MEDIUM
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.