CVE-2021-20598 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R08/16/32/120SFCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to lockout a legitimate user by continuously trying login with incorrect password. | |||||
CVE-2021-20593 | 1 Mitsubishi | 38 Ae-200a, Ae-200a Firmware, Ae-200e and 35 more | 2024-11-21 | 5.5 MEDIUM | 7.1 HIGH |
Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior) and Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) allows a remote authenticated attacker to impersonate administrators to disclose configuration information of the air conditioning system and tamper information (e.g. operation information and configuration of air conditioning system) by exploiting this vulnerability. | |||||
CVE-2021-20590 | 1 Mitsubishielectric | 12 Got2000 Gt25, Got2000 Gt25 Firmware, Got2000 Gt27 and 9 more | 2024-11-21 | 4.3 MEDIUM | 7.5 HIGH |
Improper authentication vulnerability in GOT2000 series GT27 model VNC server versions 01.39.010 and prior, GOT2000 series GT25 model VNC server versions 01.39.010 and prior, GOT2000 series GT21 model GT2107-WTBD VNC server versions 01.40.000 and prior, GOT2000 series GT21 model GT2107-WTSD VNC server versions 01.40.000 and prior, GOT SIMPLE series GS21 model GS2110-WTBD-N VNC server versions 01.40.000 and prior and GOT SIMPLE series GS21 model GS2107-WTBD-N VNC server versions 01.40.000 and prior allows a remote unauthenticated attacker to gain unauthorized access via specially crafted packets when the "VNC server" function is used. | |||||
CVE-2021-20578 | 2 Ibm, Redhat | 2 Cloud Pak For Security, Openshift | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
IBM Cloud Pak for Security (CP4S) 1.7.0.0, 1.7.1.0, 1.7.2.0, and 1.8.0.0 could allow an attacker to perform unauthorized actions due to improper or missing authentication controls. IBM X-Force ID: 199282. | |||||
CVE-2021-20288 | 4 Debian, Fedoraproject, Linuxfoundation and 1 more | 4 Debian Linux, Fedora, Ceph and 1 more | 2024-11-21 | 6.5 MEDIUM | 7.2 HIGH |
An authentication flaw was found in ceph in versions before 14.2.20. When the monitor handles CEPHX_GET_AUTH_SESSION_KEY requests, it doesn't sanitize other_keys, allowing key reuse. An attacker who can request a global_id can exploit the ability of any user to request a global_id previously associated with another user, as ceph does not force the reuse of old keys to generate new ones. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability. | |||||
CVE-2021-20278 | 1 Kiali | 1 Kiali | 2024-11-21 | 5.8 MEDIUM | 6.5 MEDIUM |
An authentication bypass vulnerability was found in Kiali in versions before 1.31.0 when the authentication strategy `OpenID` is used. When RBAC is enabled, Kiali assumes that some of the token validation is handled by the underlying cluster. When OpenID `implicit flow` is used with RBAC turned off, this token validation doesn't occur, and this allows a malicious user to bypass the authentication. | |||||
CVE-2021-20168 | 1 Netgear | 2 Rax43, Rax43 Firmware | 2024-11-21 | 7.2 HIGH | 6.8 MEDIUM |
Netgear RAX43 version 1.0.3.96 does not have sufficient protections to the UART interface. A malicious actor with physical access to the device is able to connect to the UART port via a serial connection, login with default credentials, and execute commands as the root user. These default credentials are admin:admin. | |||||
CVE-2021-20161 | 1 Trendnet | 2 Tew-827dru, Tew-827dru Firmware | 2024-11-21 | 7.2 HIGH | 6.8 MEDIUM |
Trendnet AC2600 TEW-827DRU version 2.08B01 does not have sufficient protections for the UART functionality. A malicious actor with physical access to the device is able to connect to the UART port via a serial connection. No username or password is required and the user is given a root shell with full control of the device. | |||||
CVE-2021-20145 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Gryphon Tower routers contain an unprotected openvpn configuration file which can grant attackers access to the Gryphon homebound VPN network which exposes the LAN interfaces of other users' devices connected to the same service. An attacker could leverage this to make configuration changes to, or otherwise attack victims' devices as though they were on an adjacent network. | |||||
CVE-2021-20092 | 1 Buffalo | 4 Wsr-2533dhp3-bk, Wsr-2533dhp3-bk Firmware, Wsr-2533dhpl2-bk and 1 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
The web interfaces of Buffalo WSR-2533DHPL2 firmware version <= 1.02 and WSR-2533DHP3 firmware version <= 1.24 do not properly restrict access to sensitive information from an unauthorized actor. | |||||
CVE-2021-20020 | 1 Sonicwall | 1 Global Management System | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
A command execution vulnerability in SonicWall GMS 9.3 allows a remote unauthenticated attacker to locally escalate privilege to root. | |||||
CVE-2021-20018 | 1 Sonicwall | 2 Sma100, Sma100 Firmware | 2024-11-21 | 4.0 MEDIUM | 4.9 MEDIUM |
A post-authenticated vulnerability in SonicWall SMA100 allows an attacker to export the configuration file to the specified email address. This vulnerability impacts SMA100 version 10.2.0.5 and earlier. | |||||
CVE-2021-1950 | 1 Qualcomm | 184 Ar8035, Ar8035 Firmware, Csr8811 and 181 more | 2024-11-21 | 7.2 HIGH | 7.8 HIGH |
Improper cleaning of secure memory between authenticated users can lead to face authentication bypass in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Wired Infrastructure and Networking | |||||
CVE-2021-1863 | 1 Apple | 2 Ipados, Iphone Os | 2024-11-21 | 2.1 LOW | 2.4 LOW |
An issue existed with authenticating the action triggered by an NFC tag. The issue was addressed with improved action authentication. This issue is fixed in iOS 14.5 and iPadOS 14.5. A person with physical access to an iOS device may be able to place phone calls to any phone number. | |||||
CVE-2021-1725 | 1 Microsoft | 1 Bot Framework Software Development Kit | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
Bot Framework SDK Information Disclosure Vulnerability | |||||
CVE-2021-1561 | 1 Cisco | 1 Secure Email And Web Manager | 2024-11-21 | 5.5 MEDIUM | 5.4 MEDIUM |
A vulnerability in the spam quarantine feature of Cisco Secure Email and Web Manager, formerly Cisco Security Management Appliance (SMA), could allow an authenticated, remote attacker to gain unauthorized access and modify the spam quarantine settings of another user. This vulnerability exists because access to the spam quarantine feature is not properly restricted. An attacker could exploit this vulnerability by sending malicious requests to an affected system. A successful exploit could allow the attacker to modify another user's spam quarantine settings, possibly disabling security controls or viewing email messages stored on the spam quarantine interfaces. | |||||
CVE-2021-1542 | 1 Cisco | 18 Sf220-24, Sf220-24 Firmware, Sf220-24p and 15 more | 2024-11-21 | 9.3 HIGH | 7.2 HIGH |
Multiple vulnerabilities in the web-based management interface of Cisco Small Business 220 Series Smart Switches could allow an attacker to do the following: Hijack a user session Execute arbitrary commands as a root user on the underlying operating system Conduct a cross-site scripting (XSS) attack Conduct an HTML injection attack For more information about these vulnerabilities, see the Details section of this advisory. | |||||
CVE-2021-1541 | 1 Cisco | 18 Sf220-24, Sf220-24 Firmware, Sf220-24p and 15 more | 2024-11-21 | 9.0 HIGH | 7.2 HIGH |
Multiple vulnerabilities in the web-based management interface of Cisco Small Business 220 Series Smart Switches could allow an attacker to do the following: Hijack a user session Execute arbitrary commands as a root user on the underlying operating system Conduct a cross-site scripting (XSS) attack Conduct an HTML injection attack For more information about these vulnerabilities, see the Details section of this advisory. | |||||
CVE-2021-1472 | 1 Cisco | 18 Rv160, Rv160 Firmware, Rv160w and 15 more | 2024-11-21 | 7.5 HIGH | 5.3 MEDIUM |
Multiple vulnerabilities exist in the web-based management interface of Cisco Small Business RV Series Routers. A remote attacker could execute arbitrary commands or bypass authentication and upload files on an affected device. For more information about these vulnerabilities, see the Details section of this advisory. | |||||
CVE-2021-1468 | 1 Cisco | 2 Catalyst Sd-wan Manager, Sd-wan Vmanage | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
Multiple vulnerabilities in Cisco SD-WAN vManage Software could allow an unauthenticated, remote attacker to execute arbitrary code or gain access to sensitive information, or allow an authenticated, local attacker to gain escalated privileges or gain unauthorized access to the application. For more information about these vulnerabilities, see the Details section of this advisory. |