CVE-2024-9793

A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/ixout/iotVuls/blob/main/Tenda/ac1206_003/report.md Exploit Third Party Advisory
https://github.com/ixout/iotVuls/blob/main/Tenda/ac1206_004/report.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.279946 Permissions Required VDB Entry
https://vuldb.com/?id.279946 Third Party Advisory VDB Entry
https://vuldb.com/?submit.418061 Third Party Advisory VDB Entry
https://www.tenda.com.cn/ Product
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*

History

01 Nov 2024, 14:36

Type Values Removed Values Added
References () https://github.com/ixout/iotVuls/blob/main/Tenda/ac1206_003/report.md - () https://github.com/ixout/iotVuls/blob/main/Tenda/ac1206_003/report.md - Exploit, Third Party Advisory
References () https://github.com/ixout/iotVuls/blob/main/Tenda/ac1206_004/report.md - () https://github.com/ixout/iotVuls/blob/main/Tenda/ac1206_004/report.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.279946 - () https://vuldb.com/?ctiid.279946 - Permissions Required, VDB Entry
References () https://vuldb.com/?id.279946 - () https://vuldb.com/?id.279946 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.418061 - () https://vuldb.com/?submit.418061 - Third Party Advisory, VDB Entry
References () https://www.tenda.com.cn/ - () https://www.tenda.com.cn/ - Product
CPE cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*
First Time Tenda ac1206
Tenda ac1206 Firmware
Tenda
CVSS v2 : 6.5
v3 : 6.3
v2 : 6.5
v3 : 9.8
CWE CWE-78

15 Oct 2024, 12:58

Type Values Removed Values Added
Summary
  • (es) Se ha detectado una vulnerabilidad clasificada como crítica en Tenda AC1206 hasta la versión 15.03.06.23. Esta vulnerabilidad afecta a la función ate_iwpriv_set/ate_ifconfig_set del archivo /goform/ate. La manipulación conduce a la inyección de comandos. El ataque puede iniciarse de forma remota. El exploit se ha hecho público y puede utilizarse. Se contactó al proveedor con antelación sobre esta revelación, pero no respondió de ninguna manera.

10 Oct 2024, 16:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-10-10 16:15

Updated : 2024-11-01 14:36


NVD link : CVE-2024-9793

Mitre link : CVE-2024-9793

CVE.ORG link : CVE-2024-9793


JSON object : View

Products Affected

tenda

  • ac1206_firmware
  • ac1206
CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

CWE-77

Improper Neutralization of Special Elements used in a Command ('Command Injection')