CVE-2024-7175

A vulnerability has been found in TOTOLINK A3600R 4.1.2cu.5182_B20201102 and classified as critical. This vulnerability affects the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ipDoamin leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272596. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setDiagnosisCfg.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.272596 Permissions Required Third Party Advisory
https://vuldb.com/?id.272596 Third Party Advisory
https://vuldb.com/?submit.378042 Third Party Advisory
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setDiagnosisCfg.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.272596 Permissions Required Third Party Advisory
https://vuldb.com/?id.272596 Third Party Advisory
https://vuldb.com/?submit.378042 Third Party Advisory
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:totolink:a3600r_firmware:4.1.2cu.5182_b20201102:*:*:*:*:*:*:*
cpe:2.3:h:totolink:a3600r:-:*:*:*:*:*:*:*

History

21 Nov 2024, 09:51

Type Values Removed Values Added
CVSS v2 : 6.5
v3 : 8.8
v2 : 6.5
v3 : 6.3
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setDiagnosisCfg.md - Exploit, Third Party Advisory () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setDiagnosisCfg.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.272596 - Permissions Required, Third Party Advisory () https://vuldb.com/?ctiid.272596 - Permissions Required, Third Party Advisory
References () https://vuldb.com/?id.272596 - Third Party Advisory () https://vuldb.com/?id.272596 - Third Party Advisory
References () https://vuldb.com/?submit.378042 - Third Party Advisory () https://vuldb.com/?submit.378042 - Third Party Advisory

06 Aug 2024, 12:57

Type Values Removed Values Added
First Time Totolink a3600r Firmware
Totolink a3600r
Totolink
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setDiagnosisCfg.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setDiagnosisCfg.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.272596 - () https://vuldb.com/?ctiid.272596 - Permissions Required, Third Party Advisory
References () https://vuldb.com/?id.272596 - () https://vuldb.com/?id.272596 - Third Party Advisory
References () https://vuldb.com/?submit.378042 - () https://vuldb.com/?submit.378042 - Third Party Advisory
CPE cpe:2.3:o:totolink:a3600r_firmware:4.1.2cu.5182_b20201102:*:*:*:*:*:*:*
cpe:2.3:h:totolink:a3600r:-:*:*:*:*:*:*:*
CVSS v2 : 6.5
v3 : 6.3
v2 : 6.5
v3 : 8.8

29 Jul 2024, 14:12

Type Values Removed Values Added
Summary
  • (es) Una vulnerabilidad ha sido encontrada en TOTOLINK A3600R 4.1.2cu.5182_B20201102 y clasificada como crítica. Esta vulnerabilidad afecta a la función setDiagnosisCfg del archivo /cgi-bin/cstecgi.cgi. La manipulación del argumento ipDoamin conduce a la inyección de comandos del sistema operativo. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador de esta vulnerabilidad es VDB-272596. NOTA: Se contactó al proveedor tempranamente sobre esta divulgación, pero no respondió de ninguna manera.

29 Jul 2024, 01:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-07-29 01:15

Updated : 2024-11-21 09:51


NVD link : CVE-2024-7175

Mitre link : CVE-2024-7175

CVE.ORG link : CVE-2024-7175


JSON object : View

Products Affected

totolink

  • a3600r_firmware
  • a3600r
CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')