CVE-2024-7174

A vulnerability, which was classified as critical, was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. This affects the function setdeviceName of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument deviceMac/deviceName leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272595. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setDeviceName.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.272595 Permissions Required Third Party Advisory
https://vuldb.com/?id.272595 Third Party Advisory
https://vuldb.com/?submit.378041 Third Party Advisory
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:totolink:a3600r_firmware:4.1.2cu.5182_b20201102:*:*:*:*:*:*:*
cpe:2.3:h:totolink:a3600r:-:*:*:*:*:*:*:*

History

06 Aug 2024, 13:14

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setDeviceName.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setDeviceName.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.272595 - () https://vuldb.com/?ctiid.272595 - Permissions Required, Third Party Advisory
References () https://vuldb.com/?id.272595 - () https://vuldb.com/?id.272595 - Third Party Advisory
References () https://vuldb.com/?submit.378041 - () https://vuldb.com/?submit.378041 - Third Party Advisory
CWE CWE-77
First Time Totolink a3600r Firmware
Totolink a3600r
Totolink
CPE cpe:2.3:o:totolink:a3600r_firmware:4.1.2cu.5182_b20201102:*:*:*:*:*:*:*
cpe:2.3:h:totolink:a3600r:-:*:*:*:*:*:*:*

29 Jul 2024, 14:12

Type Values Removed Values Added
Summary
  • (es) Una vulnerabilidad fue encontrada en TOTOLINK A3600R 4.1.2cu.5182_B20201102 y clasificada como crítica. Esto afecta la función setdeviceName del archivo /cgi-bin/cstecgi.cgi. La manipulación del argumento deviceMac/deviceName provoca un desbordamiento de búfer. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-272595. NOTA: Se contactó al proveedor tempranamente sobre esta divulgación, pero no respondió de ninguna manera.

29 Jul 2024, 00:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-07-29 00:15

Updated : 2024-08-06 13:14


NVD link : CVE-2024-7174

Mitre link : CVE-2024-7174

CVE.ORG link : CVE-2024-7174


JSON object : View

Products Affected

totolink

  • a3600r_firmware
  • a3600r
CWE
CWE-77

Improper Neutralization of Special Elements used in a Command ('Command Injection')

CWE-120

Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')