CVE-2024-2853

A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Configurations

Configuration 1 (hide)

AND
OR cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*
cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac10u:1.0:*:*:*:*:*:*:*

History

21 Nov 2024, 09:10

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md - Exploit, Third Party Advisory () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.257777 - Permissions Required () https://vuldb.com/?ctiid.257777 - Permissions Required
References () https://vuldb.com/?id.257777 - Third Party Advisory () https://vuldb.com/?id.257777 - Third Party Advisory
CVSS v2 : 6.5
v3 : 9.8
v2 : 6.5
v3 : 6.3

26 Mar 2024, 03:15

Type Values Removed Values Added
Summary
  • (es) Se encontró una vulnerabilidad en Tenda AC10U 15.03.06.48/15.03.06.49. Ha sido calificada como crítica. Este problema afecta la función formSetSambaConf del archivo /goform/setsambacfg. La manipulación del argumento usbName conduce a la inyección de comandos del sistema operativo. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. A esta vulnerabilidad se le asignó el identificador VDB-257777. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.257777 - () https://vuldb.com/?ctiid.257777 - Permissions Required
References () https://vuldb.com/?id.257777 - () https://vuldb.com/?id.257777 - Third Party Advisory
CVSS v2 : 6.5
v3 : 6.3
v2 : 6.5
v3 : 9.8
CPE cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*
cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac10u:1.0:*:*:*:*:*:*:*
First Time Tenda
Tenda ac10u Firmware
Tenda ac10u

24 Mar 2024, 05:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-03-24 05:15

Updated : 2024-11-21 09:10


NVD link : CVE-2024-2853

Mitre link : CVE-2024-2853

CVE.ORG link : CVE-2024-2853


JSON object : View

Products Affected

tenda

  • ac10u_firmware
  • ac10u
CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')