A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/html/ssa-871717.html | Vendor Advisory |
Configurations
History
04 Oct 2024, 16:50
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:a:siemens:polarion_alm:*:*:*:*:*:*:*:* | |
First Time |
Siemens
Siemens polarion Alm |
|
References | () https://cert-portal.siemens.com/productcert/html/ssa-871717.html - Vendor Advisory | |
CVSS |
v2 : v3 : |
v2 : unknown
v3 : 9.8 |
15 May 2024, 08:15
Type | Values Removed | Values Added |
---|---|---|
Summary | (en) A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code. |
14 May 2024, 16:16
Type | Values Removed | Values Added |
---|---|---|
Summary | (en) A vulnerability has been identified in Polarion ALM (All versions < V2024.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code. |
13 Feb 2024, 09:15
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2024-02-13 09:15
Updated : 2024-10-04 16:50
NVD link : CVE-2024-23813
Mitre link : CVE-2024-23813
CVE.ORG link : CVE-2024-23813
JSON object : View
Products Affected
siemens
- polarion_alm
CWE
CWE-287
Improper Authentication