External Control of Critical State Data (CWE-642) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated user to modify device I/O connections leading to unexpected behavior that in some circumstances could compromise site physical security controls. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes.
This issue affects: Gallagher Controller 6000 and 7000
9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), 8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)), 8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.
References
Configurations
No configuration.
History
11 Jul 2024, 13:05
Type | Values Removed | Values Added |
---|---|---|
Summary |
|
11 Jul 2024, 03:15
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2024-07-11 03:15
Updated : 2024-07-11 13:05
NVD link : CVE-2024-22387
Mitre link : CVE-2024-22387
CVE.ORG link : CVE-2024-22387
JSON object : View
Products Affected
No product.
CWE
CWE-642
External Control of Critical State Data