CVE-2024-10914

A vulnerability was found in D-Link DNS-320, DNS-320LW, DNS-325 and DNS-340L up to 20241028. It has been declared as critical. Affected by this vulnerability is the function cgi_user_add of the file /cgi-bin/account_mgr.cgi?cmd=cgi_user_add. The manipulation of the argument name leads to os command injection. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:dlink:dns-320_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dns-320:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:dlink:dns-320lw_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dns-320lw:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:dlink:dns-325_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dns-325:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:dlink:dns-340l_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dns-340l:-:*:*:*:*:*:*:*

History

08 Nov 2024, 19:53

Type Values Removed Values Added
References () https://netsecfish.notion.site/Command-Injection-Vulnerability-in-name-parameter-for-D-Link-NAS-12d6b683e67c80c49ffcc9214c239a07?pvs=4 - () https://netsecfish.notion.site/Command-Injection-Vulnerability-in-name-parameter-for-D-Link-NAS-12d6b683e67c80c49ffcc9214c239a07?pvs=4 - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.283309 - () https://vuldb.com/?ctiid.283309 - Permissions Required
References () https://vuldb.com/?id.283309 - () https://vuldb.com/?id.283309 - Permissions Required, Third Party Advisory
References () https://vuldb.com/?submit.432847 - () https://vuldb.com/?submit.432847 - Third Party Advisory
References () https://www.dlink.com/ - () https://www.dlink.com/ - Product
CPE cpe:2.3:o:dlink:dns-320_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dns-320lw:-:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dns-340l:-:*:*:*:*:*:*:*
cpe:2.3:o:dlink:dns-325_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dns-320:-:*:*:*:*:*:*:*
cpe:2.3:o:dlink:dns-340l_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dlink:dns-320lw_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dns-325:-:*:*:*:*:*:*:*
First Time Dlink dns-325 Firmware
Dlink dns-320lw Firmware
Dlink dns-340l
Dlink
Dlink dns-320 Firmware
Dlink dns-325
Dlink dns-320lw
Dlink dns-320
Dlink dns-340l Firmware
Summary
  • (es) Se ha detectado una vulnerabilidad en los sistemas DNS-320, DNS-320LW, DNS-325 y DNS-340L de D-Link hasta 20241028. Se ha declarado como crítica. Esta vulnerabilidad afecta a la función cgi_user_add del archivo /cgi-bin/account_mgr.cgi?cmd=cgi_user_add. La manipulación del nombre del argumento provoca la inyección de comandos en el sistema operativo. El ataque se puede lanzar de forma remota. La complejidad de un ataque es bastante alta. La explotación parece ser difícil. El exploit se ha hecho público y puede utilizarse.
CVSS v2 : 7.6
v3 : 8.1
v2 : 7.6
v3 : 9.8

06 Nov 2024, 14:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-11-06 14:15

Updated : 2024-11-08 19:53


NVD link : CVE-2024-10914

Mitre link : CVE-2024-10914

CVE.ORG link : CVE-2024-10914


JSON object : View

Products Affected

dlink

  • dns-340l
  • dns-340l_firmware
  • dns-325_firmware
  • dns-325
  • dns-320
  • dns-320lw_firmware
  • dns-320lw
  • dns-320_firmware
CWE
CWE-707

Improper Neutralization

CWE-74

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')

CWE-78