CVE-2024-0932

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/setSmartPowerManagement.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.252137 Permissions Required Third Party Advisory
https://vuldb.com/?id.252137 Third Party Advisory
https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/setSmartPowerManagement.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.252137 Permissions Required Third Party Advisory
https://vuldb.com/?id.252137 Third Party Advisory
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*
cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*

History

21 Nov 2024, 08:47

Type Values Removed Values Added
References () https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/setSmartPowerManagement.md - Exploit, Third Party Advisory () https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/setSmartPowerManagement.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.252137 - Permissions Required, Third Party Advisory () https://vuldb.com/?ctiid.252137 - Permissions Required, Third Party Advisory
References () https://vuldb.com/?id.252137 - Third Party Advisory () https://vuldb.com/?id.252137 - Third Party Advisory
CVSS v2 : 5.8
v3 : 9.8
v2 : 5.8
v3 : 4.7

01 Feb 2024, 14:08

Type Values Removed Values Added
References () https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/setSmartPowerManagement.md - () https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/setSmartPowerManagement.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.252137 - () https://vuldb.com/?ctiid.252137 - Permissions Required, Third Party Advisory
References () https://vuldb.com/?id.252137 - () https://vuldb.com/?id.252137 - Third Party Advisory
CPE cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*
cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 9.8
First Time Tendacn ac10u
Tendacn
Tendacn ac10u Firmware

26 Jan 2024, 18:29

Type Values Removed Values Added
New CVE

Information

Published : 2024-01-26 17:15

Updated : 2024-11-21 08:47


NVD link : CVE-2024-0932

Mitre link : CVE-2024-0932

CVE.ORG link : CVE-2024-0932


JSON object : View

Products Affected

tendacn

  • ac10u_firmware
  • ac10u
CWE
CWE-121

Stack-based Buffer Overflow