MachineSense FeverWarn Raspberry Pi-based devices lack input sanitization, which could allow an attacker on an adjacent network to send a message running commands or could overflow the stack.
References
Link | Resource |
---|---|
https://machinesense.com/pages/about-machinesense | Product |
https://www.cisa.gov/news-events/ics-advisories/icsa-24-025-01 | Third Party Advisory US Government Resource |
https://machinesense.com/pages/about-machinesense | Product |
https://www.cisa.gov/news-events/ics-advisories/icsa-24-025-01 | Third Party Advisory US Government Resource |
Configurations
Configuration 1 (hide)
AND |
|
History
21 Nov 2024, 08:33
Type | Values Removed | Values Added |
---|---|---|
References | () https://machinesense.com/pages/about-machinesense - Product | |
References | () https://www.cisa.gov/news-events/ics-advisories/icsa-24-025-01 - Third Party Advisory, US Government Resource |
08 Feb 2024, 15:50
Type | Values Removed | Values Added |
---|---|---|
First Time |
Machinesense
Machinesense feverwarn Machinesense feverwarn Firmware |
|
CVSS |
v2 : v3 : |
v2 : unknown
v3 : 8.1 |
CWE | NVD-CWE-noinfo | |
CPE | cpe:2.3:h:machinesense:feverwarn:-:*:*:*:*:*:*:* cpe:2.3:o:machinesense:feverwarn_firmware:-:*:*:*:*:*:*:* |
|
References | () https://www.cisa.gov/news-events/ics-advisories/icsa-24-025-01 - Third Party Advisory, US Government Resource | |
References | () https://machinesense.com/pages/about-machinesense - Product |
01 Feb 2024, 23:15
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2024-02-01 23:15
Updated : 2024-11-21 08:33
NVD link : CVE-2023-49610
Mitre link : CVE-2023-49610
CVE.ORG link : CVE-2023-49610
JSON object : View
Products Affected
machinesense
- feverwarn
- feverwarn_firmware
CWE