CVE-2023-45321

The Android Client application, when enrolled with the define method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*

History

21 Nov 2024, 08:26

Type Values Removed Values Added
References () https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html - Mitigation, Vendor Advisory () https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html - Mitigation, Vendor Advisory
CVSS v2 : unknown
v3 : 8.8
v2 : unknown
v3 : 8.3

06 Nov 2023, 14:44

Type Values Removed Values Added
First Time Boschrexroth ctrlx Hmi Web Panel Wr2110
Boschrexroth
Boschrexroth ctrlx Hmi Web Panel Wr2110 Firmware
Boschrexroth ctrlx Hmi Web Panel Wr2115 Firmware
Boschrexroth ctrlx Hmi Web Panel Wr2107
Boschrexroth ctrlx Hmi Web Panel Wr2115
Boschrexroth ctrlx Hmi Web Panel Wr2107 Firmware
References (MISC) https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html - (MISC) https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html - Mitigation, Vendor Advisory
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 8.8
CPE cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*
cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*
cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*
cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*
CWE CWE-319

25 Oct 2023, 18:17

Type Values Removed Values Added
New CVE

Information

Published : 2023-10-25 18:17

Updated : 2024-11-21 08:26


NVD link : CVE-2023-45321

Mitre link : CVE-2023-45321

CVE.ORG link : CVE-2023-45321


JSON object : View

Products Affected

boschrexroth

  • ctrlx_hmi_web_panel_wr2115_firmware
  • ctrlx_hmi_web_panel_wr2115
  • ctrlx_hmi_web_panel_wr2107_firmware
  • ctrlx_hmi_web_panel_wr2107
  • ctrlx_hmi_web_panel_wr2110_firmware
  • ctrlx_hmi_web_panel_wr2110
CWE
CWE-319

Cleartext Transmission of Sensitive Information