VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from
an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login
restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider
and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).
References
Link | Resource |
---|---|
https://github.com/vmware/photon/wiki/Security-Update-3.0-687 | Vendor Advisory |
https://github.com/vmware/photon/wiki/Security-Update-4.0-512 | Vendor Advisory |
https://github.com/vmware/photon/wiki/Security-Update-5.0-143 | Vendor Advisory |
https://www.vmware.com/security/advisories/VMSA-2023-0026.html | Vendor Advisory |
Configurations
Configuration 1 (hide)
AND |
|
History
21 Nov 2023, 19:59
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:a:vmware:cloud_director:*:*:*:*:*:*:*:* cpe:2.3:o:vmware:photon_os:-:*:*:*:*:*:*:* |
|
CWE | CWE-306 | |
CVSS |
v2 : v3 : |
v2 : unknown
v3 : 9.8 |
First Time |
Vmware cloud Director
Vmware Vmware photon Os |
|
References | () https://github.com/vmware/photon/wiki/Security-Update-3.0-687 - Vendor Advisory | |
References | () https://github.com/vmware/photon/wiki/Security-Update-4.0-512 - Vendor Advisory | |
References | () https://github.com/vmware/photon/wiki/Security-Update-5.0-143 - Vendor Advisory | |
References | () https://www.vmware.com/security/advisories/VMSA-2023-0026.html - Vendor Advisory |
16 Nov 2023, 16:15
Type | Values Removed | Values Added |
---|---|---|
Summary | VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5). | |
References |
|
14 Nov 2023, 21:38
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2023-11-14 21:15
Updated : 2024-02-28 20:54
NVD link : CVE-2023-34060
Mitre link : CVE-2023-34060
CVE.ORG link : CVE-2023-34060
JSON object : View
Products Affected
vmware
- photon_os
- cloud_director
CWE
CWE-306
Missing Authentication for Critical Function