During the retrofit validation process, the firmware doesn't properly check the boundaries while copying some attributes
to check. This allows a stack-based buffer overflow that could lead to a potential Remote Code Execution on the targeted
device
References
Link | Resource |
---|---|
https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf | Vendor Advisory |
https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf | Vendor Advisory |
Configurations
Configuration 1 (hide)
AND |
|
Configuration 2 (hide)
AND |
|
Configuration 3 (hide)
AND |
|
Configuration 4 (hide)
AND |
|
Configuration 5 (hide)
AND |
|
Configuration 6 (hide)
AND |
|
Configuration 7 (hide)
AND |
|
Configuration 8 (hide)
AND |
|
History
21 Nov 2024, 08:05
Type | Values Removed | Values Added |
---|---|---|
References | () https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf - Vendor Advisory | |
CVSS |
v2 : v3 : |
v2 : unknown
v3 : 9.1 |
21 Dec 2023, 19:25
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:h:idemia:sigma_lite:-:*:*:*:*:*:*:* cpe:2.3:o:idemia:morphowave_sp_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:idemia:morphowave_xp_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:idemia:morphowave_compact_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:idemia:morphowave_xp:-:*:*:*:*:*:*:* cpe:2.3:o:idemia:sigma_wide_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:idemia:sigma_lite\+_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:idemia:sigma_wide:-:*:*:*:*:*:*:* cpe:2.3:o:idemia:sigma_extreme_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:idemia:morphowave_sp:-:*:*:*:*:*:*:* cpe:2.3:h:idemia:morphowave_compact:-:*:*:*:*:*:*:* cpe:2.3:h:idemia:visionpass:-:*:*:*:*:*:*:* cpe:2.3:o:idemia:visionpass_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:idemia:sigma_lite\+:-:*:*:*:*:*:*:* cpe:2.3:o:idemia:sigma_lite_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:idemia:sigma_extreme:-:*:*:*:*:*:*:* |
|
CVSS |
v2 : v3 : |
v2 : unknown
v3 : 9.8 |
References | () https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf - Vendor Advisory | |
CWE | CWE-787 | |
First Time |
Idemia sigma Extreme
Idemia visionpass Firmware Idemia morphowave Compact Firmware Idemia sigma Lite\+ Firmware Idemia sigma Lite\+ Idemia morphowave Xp Idemia sigma Extreme Firmware Idemia sigma Lite Firmware Idemia sigma Wide Idemia morphowave Sp Firmware Idemia morphowave Xp Firmware Idemia morphowave Sp Idemia sigma Wide Firmware Idemia sigma Lite Idemia morphowave Compact Idemia Idemia visionpass |
15 Dec 2023, 13:41
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2023-12-15 12:15
Updated : 2024-11-21 08:05
NVD link : CVE-2023-33220
Mitre link : CVE-2023-33220
CVE.ORG link : CVE-2023-33220
JSON object : View
Products Affected
idemia
- morphowave_sp_firmware
- visionpass_firmware
- sigma_wide_firmware
- morphowave_sp
- sigma_lite\+
- sigma_lite\+_firmware
- sigma_extreme_firmware
- morphowave_compact_firmware
- sigma_lite
- morphowave_compact
- sigma_extreme
- morphowave_xp
- visionpass
- sigma_wide
- morphowave_xp_firmware
- sigma_lite_firmware