CVE-2023-33220

During the retrofit validation process, the firmware doesn't properly check the boundaries while copying some attributes to check. This allows a stack-based buffer overflow that could lead to a potential Remote Code Execution on the targeted device
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:idemia:sigma_lite_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:sigma_lite:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:idemia:sigma_lite\+_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:sigma_lite\+:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:idemia:sigma_extreme_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:sigma_extreme:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:idemia:sigma_wide_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:sigma_wide:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:idemia:morphowave_compact_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:morphowave_compact:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:idemia:morphowave_xp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:morphowave_xp:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:idemia:visionpass_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:visionpass:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:idemia:morphowave_sp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:morphowave_sp:-:*:*:*:*:*:*:*

History

21 Nov 2024, 08:05

Type Values Removed Values Added
References () https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf - Vendor Advisory () https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf - Vendor Advisory
CVSS v2 : unknown
v3 : 9.8
v2 : unknown
v3 : 9.1

21 Dec 2023, 19:25

Type Values Removed Values Added
CPE cpe:2.3:h:idemia:sigma_lite:-:*:*:*:*:*:*:*
cpe:2.3:o:idemia:morphowave_sp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:idemia:morphowave_xp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:idemia:morphowave_compact_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:morphowave_xp:-:*:*:*:*:*:*:*
cpe:2.3:o:idemia:sigma_wide_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:idemia:sigma_lite\+_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:sigma_wide:-:*:*:*:*:*:*:*
cpe:2.3:o:idemia:sigma_extreme_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:morphowave_sp:-:*:*:*:*:*:*:*
cpe:2.3:h:idemia:morphowave_compact:-:*:*:*:*:*:*:*
cpe:2.3:h:idemia:visionpass:-:*:*:*:*:*:*:*
cpe:2.3:o:idemia:visionpass_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:sigma_lite\+:-:*:*:*:*:*:*:*
cpe:2.3:o:idemia:sigma_lite_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:idemia:sigma_extreme:-:*:*:*:*:*:*:*
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 9.8
References () https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf - () https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf - Vendor Advisory
CWE CWE-787
First Time Idemia sigma Extreme
Idemia visionpass Firmware
Idemia morphowave Compact Firmware
Idemia sigma Lite\+ Firmware
Idemia sigma Lite\+
Idemia morphowave Xp
Idemia sigma Extreme Firmware
Idemia sigma Lite Firmware
Idemia sigma Wide
Idemia morphowave Sp Firmware
Idemia morphowave Xp Firmware
Idemia morphowave Sp
Idemia sigma Wide Firmware
Idemia sigma Lite
Idemia morphowave Compact
Idemia
Idemia visionpass

15 Dec 2023, 13:41

Type Values Removed Values Added
New CVE

Information

Published : 2023-12-15 12:15

Updated : 2024-11-21 08:05


NVD link : CVE-2023-33220

Mitre link : CVE-2023-33220

CVE.ORG link : CVE-2023-33220


JSON object : View

Products Affected

idemia

  • morphowave_sp_firmware
  • visionpass_firmware
  • sigma_wide_firmware
  • morphowave_sp
  • sigma_lite\+
  • sigma_lite\+_firmware
  • sigma_extreme_firmware
  • morphowave_compact_firmware
  • sigma_lite
  • morphowave_compact
  • sigma_extreme
  • morphowave_xp
  • visionpass
  • sigma_wide
  • morphowave_xp_firmware
  • sigma_lite_firmware
CWE
CWE-121

Stack-based Buffer Overflow

CWE-787

Out-of-bounds Write