CVE-2023-29076

A maliciously crafted MODEL, SLDASM, SAT or CATPART file when parsed through Autodesk AutoCAD 2024 and 2023 could cause memory corruption vulnerability. This vulnerability, along with other vulnerabilities, could lead to code execution in the current process.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:autodesk:autocad:*:*:*:*:*:macos:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_civil_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:macos:*:*
cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*

History

30 Nov 2023, 02:19

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 9.8
First Time Autodesk autocad Civil 3d
Autodesk autocad Architecture
Autodesk autocad Electrical
Autodesk
Autodesk autocad Advance Steel
Autodesk autocad
Autodesk autocad Map 3d
Autodesk autocad Lt
Autodesk autocad Plant 3d
Autodesk autocad Mep
Autodesk autocad Mechanical
CPE cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:macos:*:*
cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad_advance_steel:*:*:*:*:*:*:*:*
cpe:2.3:a:autodesk:autocad:*:*:*:*:*:macos:*:*
cpe:2.3:a:autodesk:autocad_civil_3d:*:*:*:*:*:*:*:*
CWE CWE-119
References () https://www.autodesk.com/trust/security-advisories/adsk-sa-2023-0018 - () https://www.autodesk.com/trust/security-advisories/adsk-sa-2023-0018 - Vendor Advisory

23 Nov 2023, 04:15

Type Values Removed Values Added
New CVE

Information

Published : 2023-11-23 04:15

Updated : 2024-02-28 20:54


NVD link : CVE-2023-29076

Mitre link : CVE-2023-29076

CVE.ORG link : CVE-2023-29076


JSON object : View

Products Affected

autodesk

  • autocad_plant_3d
  • autocad_architecture
  • autocad_advance_steel
  • autocad
  • autocad_map_3d
  • autocad_electrical
  • autocad_mep
  • autocad_mechanical
  • autocad_civil_3d
  • autocad_lt
CWE
CWE-119

Improper Restriction of Operations within the Bounds of a Memory Buffer