An Improper Link Resolution Before File Access vulnerability in console port access of Juniper Networks Junos OS on NFX Series allows an attacker to bypass console access controls. When "set system ports console insecure" is enabled, root login is disallowed for Junos OS as expected. However, the root password can be changed using "set system root-authentication plain-text-password" on NFX Series systems, leading to a possible administrative bypass with physical access to the console. Password recovery, changing the root password from a console, should not have been allowed from an insecure console. This is similar to the vulnerability described in CVE-2019-0035 but affects different platforms and in turn requires a different fix. This issue affects Juniper Networks Junos OS on NFX Series: 19.2 versions prior to 19.2R3-S7; 19.3 versions prior to 19.3R3-S8; 19.4 versions prior to 19.4R3-S12; 20.2 versions prior to 20.2R3-S8; 20.4 versions prior to 20.4R3-S7; 21.1 versions prior to 21.1R3-S5; 21.2 versions prior to 21.2R3-S4; 21.3 versions prior to 21.3R3-S3; 21.4 versions prior to 21.4R3-S2; 22.1 versions prior to 22.1R3-S1; 22.2 versions prior to 22.2R2-S1, 22.2R3; 22.3 versions prior to 22.3R1-S2, 22.3R2.
References
Link | Resource |
---|---|
https://supportportal.juniper.net/JSA70596 | Vendor Advisory |
https://supportportal.juniper.net/JSA70596 | Vendor Advisory |
Configurations
Configuration 1 (hide)
AND |
|
History
21 Nov 2024, 07:56
Type | Values Removed | Values Added |
---|---|---|
References | () https://supportportal.juniper.net/JSA70596 - Vendor Advisory |
Information
Published : 2023-04-17 22:15
Updated : 2024-11-21 07:56
NVD link : CVE-2023-28972
Mitre link : CVE-2023-28972
CVE.ORG link : CVE-2023-28972
JSON object : View
Products Affected
juniper
- nfx250
- nfx150
- junos
- nfx350
CWE
CWE-59
Improper Link Resolution Before File Access ('Link Following')