CVE-2023-27354

This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Sonos One Speaker 70.3-35220. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of the SMB directory query command. The issue results from the lack of proper validation of user-supplied data, which can result in an integer overflow before reading from memory. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-19727.
References
Link Resource
https://www.zerodayinitiative.com/advisories/ZDI-23-446/ Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:sonos:one_firmware:70.3-35220:*:*:*:*:*:*:*
cpe:2.3:h:sonos:one:-:*:*:*:*:*:*:*

Configuration 2 (hide)

OR cpe:2.3:a:sonos:s1:*:*:*:*:*:*:*:*
cpe:2.3:a:sonos:s2:*:*:*:*:*:*:*:*

History

No history.

Information

Published : 2023-04-20 22:15

Updated : 2024-02-28 20:13


NVD link : CVE-2023-27354

Mitre link : CVE-2023-27354

CVE.ORG link : CVE-2023-27354


JSON object : View

Products Affected

sonos

  • s2
  • one
  • s1
  • one_firmware
CWE
CWE-190

Integer Overflow or Wraparound