A cleartext transmission of sensitive information vulnerability exists in curl <v7.88.0 that could cause HSTS functionality to behave incorrectly when multiple URLs are requested in parallel. Using its HSTS support, curl can be instructed to use HTTPS instead of using an insecure clear-text HTTP step even when HTTP is provided in the URL. This HSTS mechanism would however surprisingly fail when multiple transfers are done in parallel as the HSTS cache file gets overwritten by the most recentlycompleted transfer. A later HTTP-only transfer to the earlier host name would then *not* get upgraded properly to HSTS.
References
Link | Resource |
---|---|
https://hackerone.com/reports/1826048 | Not Applicable |
https://security.gentoo.org/glsa/202310-12 | Third Party Advisory |
https://security.netapp.com/advisory/ntap-20230309-0006/ | Third Party Advisory |
Configurations
Configuration 1 (hide)
|
Configuration 2 (hide)
|
Configuration 3 (hide)
AND |
|
Configuration 4 (hide)
AND |
|
Configuration 5 (hide)
AND |
|
Configuration 6 (hide)
AND |
|
Configuration 7 (hide)
|
History
27 Mar 2024, 14:55
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:a:splunk:universal_forwarder:*:*:*:*:*:*:*:* cpe:2.3:a:splunk:universal_forwarder:9.1.0:*:*:*:*:*:*:* |
|
First Time |
Splunk
Splunk universal Forwarder |
20 Oct 2023, 18:57
Type | Values Removed | Values Added |
---|---|---|
First Time |
Netapp h500s Firmware
Netapp clustered Data Ontap Netapp h300s Netapp h300s Firmware Netapp Netapp h700s Firmware Netapp h410s Netapp h410s Firmware Netapp h500s Netapp h700s Netapp active Iq Unified Manager |
|
References | (CONFIRM) https://security.netapp.com/advisory/ntap-20230309-0006/ - Third Party Advisory | |
References | (GENTOO) https://security.gentoo.org/glsa/202310-12 - Third Party Advisory | |
CPE | cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:* cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:* cpe:2.3:a:netapp:clustered_data_ontap:9.0:-:*:*:*:*:*:* cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:* cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:* cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:* cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:* |
11 Oct 2023, 11:15
Type | Values Removed | Values Added |
---|---|---|
References |
|
Information
Published : 2023-02-23 20:15
Updated : 2024-03-27 14:55
NVD link : CVE-2023-23915
Mitre link : CVE-2023-23915
CVE.ORG link : CVE-2023-23915
JSON object : View
Products Affected
netapp
- h700s
- h300s
- h300s_firmware
- h410s_firmware
- h500s
- clustered_data_ontap
- h700s_firmware
- active_iq_unified_manager
- h410s
- h500s_firmware
haxx
- curl
splunk
- universal_forwarder
CWE
CWE-319
Cleartext Transmission of Sensitive Information