{"id": "CVE-2023-1968", "metrics": {"cvssMetricV31": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "cvssData": {"scope": "CHANGED", "version": "3.1", "baseScore": 10.0, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 6.0, "exploitabilityScore": 3.9}, {"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2023-04-28T19:15:16.647", "references": [{"url": "https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html", "tags": ["Vendor Advisory"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-117-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-117-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-1327"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "NVD-CWE-noinfo"}]}], "descriptions": [{"lang": "en", "value": "\nInstruments with Illumina Universal Copy Service v2.x are vulnerable due to binding to an unrestricted IP address. An unauthenticated malicious actor could use UCS to listen on all IP addresses, including those capable of accepting remote communications. \n\n\n\n\n\n\n\n"}], "lastModified": "2024-11-21T07:40:14.970", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:iscan_firmware:4.0.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B5000279-D40B-4526-B911-9E0641736EE1"}, {"criteria": "cpe:2.3:o:illumina:iscan_firmware:4.0.5:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BD7BE281-02B5-4B87-A7E2-D0E3BB5309CF"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:iscan:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "08732A94-734B-486E-AB2C-A2E2CA3C66AE"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:iseq_100_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D22304CE-8F36-4B51-BAA2-E2C564C04CDF"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:iseq_100:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0136ED72-BF05-404D-910A-DA5B73F69771"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:miniseq_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E4B7C1F7-D185-4C72-B23C-A21103267CD6", "versionStartIncluding": "2.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:miniseq:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "2DA69772-E795-4A64-A6A1-0BDD503D263B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:miseq_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CC028805-6ED3-455B-8F4C-95A8B8C5E756", "versionStartIncluding": "4.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:miseq:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "8AFB0D5A-AF5A-4A84-963F-C6307ADCFF4E"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:miseqdx_firmware:*:*:*:*:-:*:*:*", "vulnerable": true, "matchCriteriaId": "E97A49E3-4B87-4FE5-8FD4-5B36C61A0650", "versionStartIncluding": "4.0.1"}, {"criteria": "cpe:2.3:o:illumina:miseqdx_firmware:4.0:*:*:*:ruo:*:*:*", "vulnerable": true, "matchCriteriaId": "BE1CBD4E-42B1-42C6-9B3F-4F715A5DBF6D"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:miseqdx:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "CBD56D9E-B16C-4ED4-A2E4-E73A3A9A599B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:nextseq_500_firmware:4.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "22E34BB5-591C-4889-851E-9A66212C8B8C"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:nextseq_500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "1C7AEA5A-707D-4BF4-9DF6-BDE6E6D97B60"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:nextseq_550_firmware:4.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D0D02B5D-7E8A-41CD-BE27-5B012BE5C016"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:nextseq_550:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BF742B4D-0FC5-443A-8040-7B0A1B298707"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:nextseq_550dx_firmware:*:*:*:*:-:*:*:*", "vulnerable": true, "matchCriteriaId": "93DC004D-271D-4075-9828-E88CD7FFC403", "versionEndIncluding": "1.3.1", "versionStartIncluding": "1.0.0"}, {"criteria": "cpe:2.3:o:illumina:nextseq_550dx_firmware:*:*:*:*:-:*:*:*", "vulnerable": true, "matchCriteriaId": "E199B789-BF31-40AC-B15E-31A97257002B", "versionStartIncluding": "1.3.3"}, {"criteria": "cpe:2.3:o:illumina:nextseq_550dx_firmware:4.0:*:*:*:ruo:*:*:*", "vulnerable": true, "matchCriteriaId": "78D581A6-38A5-4F0A-A5CB-B25A9337EE78"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:nextseq_550dx:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "B3D5AB9D-7EAA-45F2-A10F-A2D142B20D3D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:nextseq_1000_firmware:1.4.1:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "94B82675-AA38-4584-82BD-9C376F80EA49"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:nextseq_1000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "93589C3C-F577-4C67-962F-166E28911ED2"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:nextseq_2000_firmware:1.4.1:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6671E6F8-85D5-4970-98FE-6189C8F98852"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:nextseq_2000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "753D8FDF-5D25-46B9-8E66-30FB8E8A9A87"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:illumina:novaseq_6000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3A429D26-AF22-4AC2-AB02-76C72B9B9B05", "versionEndIncluding": "1.7"}, {"criteria": "cpe:2.3:o:illumina:novaseq_6000_firmware:1.8:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B4C702B1-4BAD-4E32-9659-D9F5C3F2F922"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:illumina:novaseq_6000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0D879686-89E7-4152-AEF9-DC8A33FDA4A5"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}