CVE-2022-46144

A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:6gk5622-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5622-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:6gk5626-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5626-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:siemens:6gk5632-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5632-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:siemens:6gk5636-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5636-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:6gk5642-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5642-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:6gk5646-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5646-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:6gk5622-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5622-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:6gk5626-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5626-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:siemens:6gk5632-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5632-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:6gk5636-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5636-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:siemens:6gk5642-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5642-2gs00-2ac2:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:siemens:6gk5646-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:6gk5646-2gs00-2ac2:-:*:*:*:*:*:*:*

History

21 Nov 2024, 07:30

Type Values Removed Values Added
References () https://cert-portal.siemens.com/productcert/html/ssa-413565.html - () https://cert-portal.siemens.com/productcert/html/ssa-413565.html -
References () https://cert-portal.siemens.com/productcert/html/ssa-690517.html - () https://cert-portal.siemens.com/productcert/html/ssa-690517.html -
References () https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf - Patch, Vendor Advisory () https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf - Patch, Vendor Advisory

10 Sep 2024, 10:15

Type Values Removed Values Added
Summary (en) A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive. (en) A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.

11 Jun 2024, 09:15

Type Values Removed Values Added
Summary (en) A vulnerability has been identified in SCALANCE SC622-2C (All versions < V2.3), SCALANCE SC622-2C (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (All versions < V2.3), SCALANCE SC626-2C (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (All versions < V2.3), SCALANCE SC632-2C (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (All versions < V2.3), SCALANCE SC636-2C (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (All versions < V2.3), SCALANCE SC642-2C (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (All versions < V2.3), SCALANCE SC646-2C (All versions >= V2.3 < V3.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive. (en) A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.
References
  • () https://cert-portal.siemens.com/productcert/html/ssa-413565.html -
  • () https://cert-portal.siemens.com/productcert/html/ssa-690517.html -

10 Oct 2023, 11:15

Type Values Removed Values Added
Summary A vulnerability has been identified in SCALANCE SC622-2C (All versions < V2.3), SCALANCE SC622-2C (All versions >= 2.3 < V3.0), SCALANCE SC626-2C (All versions < V2.3), SCALANCE SC626-2C (All versions >= 2.3 < V3.0), SCALANCE SC632-2C (All versions < V2.3), SCALANCE SC632-2C (All versions >= 2.3 < V3.0), SCALANCE SC636-2C (All versions < V2.3), SCALANCE SC636-2C (All versions >= 2.3 < V3.0), SCALANCE SC642-2C (All versions < V2.3), SCALANCE SC642-2C (All versions >= 2.3 < V3.0), SCALANCE SC646-2C (All versions < V2.3), SCALANCE SC646-2C (All versions >= 2.3 < V3.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive. A vulnerability has been identified in SCALANCE SC622-2C (All versions < V2.3), SCALANCE SC622-2C (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (All versions < V2.3), SCALANCE SC626-2C (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (All versions < V2.3), SCALANCE SC632-2C (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (All versions < V2.3), SCALANCE SC636-2C (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (All versions < V2.3), SCALANCE SC642-2C (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (All versions < V2.3), SCALANCE SC646-2C (All versions >= V2.3 < V3.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.

Information

Published : 2022-12-13 16:15

Updated : 2024-11-21 07:30


NVD link : CVE-2022-46144

Mitre link : CVE-2022-46144

CVE.ORG link : CVE-2022-46144


JSON object : View

Products Affected

siemens

  • 6gk5636-2gs00-2ac2_firmware
  • 6gk5646-2gs00-2ac2
  • 6gk5632-2gs00-2ac2
  • 6gk5626-2gs00-2ac2
  • 6gk5642-2gs00-2ac2
  • 6gk5646-2gs00-2ac2_firmware
  • 6gk5642-2gs00-2ac2_firmware
  • 6gk5636-2gs00-2ac2
  • 6gk5626-2gs00-2ac2_firmware
  • 6gk5622-2gs00-2ac2_firmware
  • 6gk5632-2gs00-2ac2_firmware
  • 6gk5622-2gs00-2ac2
CWE
CWE-664

Improper Control of a Resource Through its Lifetime

NVD-CWE-Other