CVE-2022-40225

A vulnerability has been identified in SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). Casting an internal value could lead to floating point exception under certain circumstances. This could allow an attacker to cause a denial of service condition on affected devices.
References
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*

History

24 Jun 2024, 19:39

Type Values Removed Values Added
First Time Siemens
Siemens siplus Tim 1531 Irc Firmware
Siemens siplus Tim 1531 Irc
CVSS v2 : unknown
v3 : 6.5
v2 : unknown
v3 : 7.5
CPE cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:*:*:*:*:*:*:*:*
References () https://cert-portal.siemens.com/productcert/html/ssa-337522.html - () https://cert-portal.siemens.com/productcert/html/ssa-337522.html - Patch, Vendor Advisory

11 Jun 2024, 15:15

Type Values Removed Values Added
Summary
  • (es) **RECHAZADA** NO UTILICE ESTE NÚMERO DE CANDIDATO. ID de consulta: ninguno. Motivo: Este candidato fue retirado por su CNA. Una investigación más exhaustiva demostró que no se trataba de un problema de seguridad. Notas: ninguna.
Summary (en) Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none. (en) A vulnerability has been identified in SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). Casting an internal value could lead to floating point exception under certain circumstances. This could allow an attacker to cause a denial of service condition on affected devices.
CWE CWE-681
References
  • () https://cert-portal.siemens.com/productcert/html/ssa-337522.html -
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 6.5

07 Nov 2023, 03:52

Type Values Removed Values Added
Summary ** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none. Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none.

Information

Published : 2022-11-10 22:15

Updated : 2024-06-24 19:39


NVD link : CVE-2022-40225

Mitre link : CVE-2022-40225

CVE.ORG link : CVE-2022-40225


JSON object : View

Products Affected

siemens

  • siplus_tim_1531_irc_firmware
  • siplus_tim_1531_irc
CWE
CWE-681

Incorrect Conversion between Numeric Types