A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf | Vendor Advisory |
Configurations
Configuration 1 (hide)
|
Configuration 2 (hide)
|
History
21 Nov 2024, 07:17
Type | Values Removed | Values Added |
---|---|---|
References | () https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf - Vendor Advisory |
Information
Published : 2022-09-13 10:15
Updated : 2024-11-21 07:17
NVD link : CVE-2022-39141
Mitre link : CVE-2022-39141
CVE.ORG link : CVE-2022-39141
JSON object : View
Products Affected
siemens
- parasolid
- simcenter_femap
CWE
CWE-125
Out-of-bounds Read