{"id": "CVE-2022-29560", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 10.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.2, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "HIGH", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.2}]}, "published": "2022-07-12T10:15:10.493", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf", "tags": ["Patch", "Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599506.pdf", "tags": ["Patch", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-77"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-77"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < 2.15.1), RUGGEDCOM ROX MX5000RE (All versions < 2.15.1), RUGGEDCOM ROX RX1400 (All versions < 2.15.1), RUGGEDCOM ROX RX1500 (All versions < 2.15.1), RUGGEDCOM ROX RX1501 (All versions < 2.15.1), RUGGEDCOM ROX RX1510 (All versions < 2.15.1), RUGGEDCOM ROX RX1511 (All versions < 2.15.1), RUGGEDCOM ROX RX1512 (All versions < 2.15.1), RUGGEDCOM ROX RX1524 (All versions < 2.15.1), RUGGEDCOM ROX RX1536 (All versions < 2.15.1), RUGGEDCOM ROX RX5000 (All versions < 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en RUGGEDCOM ROX MX5000 (Todas las versiones anteriores a 2.15.1), RUGGEDCOM ROX MX5000RE (Todas las versiones anteriores a 2.15.1), RUGGEDCOM ROX RX1400 (Todas las versiones anteriores a 2.15.1), RUGGEDCOM ROX RX1500 (Todas las versiones anteriores a 2.15.1), RUGGEDCOM ROX RX1501 (Todas las versiones anteriores a 2.15. 1), RUGGEDCOM ROX RX1510 (Todas las versiones anteriores a 2.15.1), RUGGEDCOM ROX RX1511 (Todas las versiones anteriores a 2.15.1), RUGGEDCOM ROX RX1512 (Todas las versiones anteriores a 2.15. 1), RUGGEDCOM ROX RX1524 (Todas las versiones anteriores a 2.15.1), RUGGEDCOM ROX RX1536 (Todas las versiones anteriores a 2.15.1), RUGGEDCOM ROX RX5000 (Todas las versiones anteriores a 2.15.1). Los dispositivos afectados no comprueban correctamente la entrada del usuario, lo que los hace susceptibles a la inyecci\u00f3n de comandos. Un atacante con acceso al shell o al CLI web con privilegios de administrador podr\u00eda acceder al sistema operativo subyacente como usuario root"}], "lastModified": "2024-11-21T06:59:19.207", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1500_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "56C961A1-00D0-4F83-B9F5-8C479704669A", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3E79B422-C844-411C-AA49-CFD73D3C6E2D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1501_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5F6ACA21-5F5E-470C-8C4A-EFDEDC6E481E", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "53AAEC5C-06EE-4C58-A981-EBF5860CEF16"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1510_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4C14C7A8-C6FF-495A-8CC9-CEAD1EA74195", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0751225A-6E9C-4281-93A4-A048920FF7C6"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1511_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "51713937-53D8-47A1-93CD-A71BB1F68082", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "8C1E56ED-1E61-4B7E-8EC0-BB2AAD57EF7B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1512_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8895AC44-D90B-4D79-9F53-CA8E5181F152", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "41ADD701-AD49-46B2-A12E-219CCED32298"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1524_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7E50BFA7-8FFA-47B8-90E5-8EF89534BB45", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F8C70D90-E8FA-4343-9027-152A99D79C82"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1536_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5124C4B1-1AF8-4231-BC19-C7396F334C9A", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C1775F3B-6F47-4134-8B4E-CF6337FF546C"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx5000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2491CAB4-A544-44F2-8634-8A55DFD8270B", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "1E0E33F2-E89B-4008-BED2-CF2296801078"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1400_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DC943E60-DA3E-4A25-9D51-CAD6352E9A10", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "12BD4008-DB6A-4749-A426-D2DE44819A9D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_mx5000re_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9FE492C0-DED5-474F-B247-735C1E4AF8D5", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "38734DFA-A5DF-4284-BD79-7C0ED6CD8A5C"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_mx5000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "EAB64CBD-AD69-4DE8-ADA8-78A59BBFE931", "versionEndExcluding": "2.15.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "DAD1B18F-9C37-48CC-92E2-9C5E66B206CB"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "productcert@siemens.com"}