CVE-2022-22806

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
References
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2022-03-09 20:15

Updated : 2024-02-28 19:09


NVD link : CVE-2022-22806

Mitre link : CVE-2022-22806

CVE.ORG link : CVE-2022-22806


JSON object : View

Products Affected

schneider-electric

  • scl_series_1029_ups_firmware
  • smt_series_1015_ups_firmware
  • smc_series_1018_ups_firmware
  • smx_series_1031_ups
  • scl_series_1036_ups
  • scl_series_1037_ups_firmware
  • smtl_series_1026_ups_firmware
  • smt_series_1015_ups
  • scl_series_1030_ups_firmware
  • scl_series_1029_ups
  • scl_series_1037_ups
  • smx_series_1031_ups_firmware
  • scl_series_1036_ups_firmware
  • scl_series_1030_ups
  • smc_series_1018_ups
  • smtl_series_1026_ups
CWE
CWE-294

Authentication Bypass by Capture-replay