CVE-2022-20925

A vulnerability in the web management interface of the Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The vulnerability is due to insufficient validation of user-supplied parameters for certain API endpoints. An attacker could exploit this vulnerability by sending crafted input to an affected API endpoint. A successful exploit could allow an attacker to execute arbitrary commands on the device with low system privileges. To successfully exploit this vulnerability, an attacker would need valid credentials for a user with Device permissions: by default, only Administrators, Security Approvers and Network Admins user accounts have these permissions.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:cisco:firepower_management_center:6.7.0:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:6.7.0.1:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:6.7.0.2:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:6.7.0.3:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.0.0:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.0.0.1:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.0.1:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.0.1.1:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.0.2:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.0.2.1:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.0.3:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.0.4:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.1.0:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.1.0.1:*:*:*:*:*:*:*
cpe:2.3:a:cisco:firepower_management_center:7.1.0.2:*:*:*:*:*:*:*

History

25 Jan 2024, 17:15

Type Values Removed Values Added
References
  • {'url': 'https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-cmd-inj-Z3B5MY35', 'name': 'https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-cmd-inj-Z3B5MY35', 'tags': ['Vendor Advisory'], 'refsource': 'MISC'}
  • () https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-cmd-inj-Z3B5MY35 -

07 Nov 2023, 03:43

Type Values Removed Values Added
Summary A vulnerability in the web management interface of the Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The vulnerability is due to insufficient validation of user-supplied parameters for certain API endpoints. An attacker could exploit this vulnerability by sending crafted input to an affected API endpoint. A successful exploit could allow an attacker to execute arbitrary commands on the device with low system privileges. To successfully exploit this vulnerability, an attacker would need valid credentials for a user with Device permissions: by default, only Administrators, Security Approvers and Network Admins user accounts have these permissions. A vulnerability in the web management interface of the Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The vulnerability is due to insufficient validation of user-supplied parameters for certain API endpoints. An attacker could exploit this vulnerability by sending crafted input to an affected API endpoint. A successful exploit could allow an attacker to execute arbitrary commands on the device with low system privileges. To successfully exploit this vulnerability, an attacker would need valid credentials for a user with Device permissions: by default, only Administrators, Security Approvers and Network Admins user accounts have these permissions.

08 Aug 2023, 14:22

Type Values Removed Values Added
CWE CWE-77 CWE-78

Information

Published : 2022-11-15 21:15

Updated : 2024-02-28 19:29


NVD link : CVE-2022-20925

Mitre link : CVE-2022-20925

CVE.ORG link : CVE-2022-20925


JSON object : View

Products Affected

cisco

  • firepower_management_center
CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

CWE-77

Improper Neutralization of Special Elements used in a Command ('Command Injection')