Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227.
References
Configurations
No configuration.
History
21 Nov 2024, 06:38
Type | Values Removed | Values Added |
---|---|---|
References | () https://www.zerodayinitiative.com/advisories/ZDI-23-450/ - |
08 May 2024, 13:15
Type | Values Removed | Values Added |
---|---|---|
Summary |
|
07 May 2024, 23:15
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2024-05-07 23:15
Updated : 2024-11-21 06:38
NVD link : CVE-2022-0369
Mitre link : CVE-2022-0369
CVE.ORG link : CVE-2022-0369
JSON object : View
Products Affected
No product.
CWE
CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')