CVE-2021-41314

Certain NETGEAR smart switches are affected by a \n injection in the web UI's password field, which - due to several faulty aspects of the authentication scheme - allows the attacker to create (or overwrite) a file with specific content (e.g., the "2" string). This leads to admin session crafting and therefore gaining full web UI admin privileges by an unauthenticated attacker. This affects GC108P before 1.0.8.2, GC108PP before 1.0.8.2, GS108Tv3 before 7.0.7.2, GS110TPP before 7.0.7.2, GS110TPv3 before 7.0.7.2, GS110TUP before 1.0.5.3, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS710TUP before 1.0.5.3, GS716TP before 1.0.4.2, GS716TPP before 1.0.4.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS750E before 1.0.1.10, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:netgear:gc108p_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gc108p:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:netgear:gc108pp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gc108pp:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:netgear:gs108t_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs108tv3:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:netgear:gs110tpp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs110tpp:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:netgear:gs110tp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs110tp:v3:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:netgear:gs110tup_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs110tup:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:netgear:gs308t_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs308t:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:netgear:gs310tp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs310tp:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:netgear:gs710tup_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs710tup:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:netgear:gs716tp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs716tp:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:netgear:gs716tpp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs716tpp:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:netgear:gs724tpp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs724tpp:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:netgear:gs724tp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs724tp:v2:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:netgear:gs728tpp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs728tpp:v2:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:netgear:gs728tp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs728tp:v2:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:netgear:gs750e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs750e:-:*:*:*:*:*:*:*

Configuration 17 (hide)

AND
cpe:2.3:o:netgear:gs752tpp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs752tpp:-:*:*:*:*:*:*:*

Configuration 18 (hide)

AND
cpe:2.3:o:netgear:gs752tp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:gs752tp:v2:*:*:*:*:*:*:*

Configuration 19 (hide)

AND
cpe:2.3:o:netgear:ms510txm_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:ms510txm:-:*:*:*:*:*:*:*

Configuration 20 (hide)

AND
cpe:2.3:o:netgear:ms510txup_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:netgear:ms510txup:-:*:*:*:*:*:*:*

History

21 Nov 2024, 06:26

Type Values Removed Values Added
References () https://gynvael.coldwind.pl/?id=742 - Exploit, Third Party Advisory () https://gynvael.coldwind.pl/?id=742 - Exploit, Third Party Advisory
References () https://kb.netgear.com/000063978/Security-Advisory-for-Multiple-Vulnerabilities-on-Some-Smart-Switches-PSV-2021-0140-PSV-2021-0144-PSV-2021-0145 - Vendor Advisory () https://kb.netgear.com/000063978/Security-Advisory-for-Multiple-Vulnerabilities-on-Some-Smart-Switches-PSV-2021-0140-PSV-2021-0144-PSV-2021-0145 - Vendor Advisory

Information

Published : 2021-09-16 22:15

Updated : 2024-11-21 06:26


NVD link : CVE-2021-41314

Mitre link : CVE-2021-41314

CVE.ORG link : CVE-2021-41314


JSON object : View

Products Affected

netgear

  • gc108pp
  • gs310tp_firmware
  • gc108p
  • gs728tpp_firmware
  • gs728tp_firmware
  • gs752tp
  • gs728tp
  • gs716tpp_firmware
  • ms510txm_firmware
  • gs308t
  • gs308t_firmware
  • gs716tp
  • ms510txup
  • gs110tp
  • gs710tup
  • gs108t_firmware
  • ms510txm
  • gs108tv3
  • gs752tp_firmware
  • gs110tp_firmware
  • gs724tp
  • gs110tup_firmware
  • ms510txup_firmware
  • gc108p_firmware
  • gs724tpp
  • gs752tpp_firmware
  • gs752tpp
  • gs750e
  • gs110tpp_firmware
  • gs710tup_firmware
  • gs728tpp
  • gs110tpp
  • gs310tp
  • gc108pp_firmware
  • gs110tup
  • gs724tp_firmware
  • gs750e_firmware
  • gs716tpp
  • gs724tpp_firmware
  • gs716tp_firmware
CWE
CWE-74

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')