CVE-2021-40359

A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.
References
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:simatic_batch:8.2:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_batch:8.2:upd_9:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_batch:9.0:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_batch:9.0:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_3:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_4:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_batch:9.1:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:14:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:16:update1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:17:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_route_control:8.2:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_route_control:9.0:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_route_control:9.1:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:15:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:16:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:16:update1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:16:update2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:16:update3:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:16:update4:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:17:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:17:update1:*:*:*:*:*:*
cpe:2.3:a:siemens:simaticpcs_7:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simaticpcs_7:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simaticpcs_7:9.1:-:*:*:*:*:*:*

History

No history.

Information

Published : 2021-11-09 12:15

Updated : 2024-02-28 18:48


NVD link : CVE-2021-40359

Mitre link : CVE-2021-40359

CVE.ORG link : CVE-2021-40359


JSON object : View

Products Affected

siemens

  • simatic_route_control
  • simatic_net_pc
  • simatic_wincc
  • simaticpcs_7
  • simatic_batch
CWE
CWE-22

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')