A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf | Patch Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf | Patch Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf | Patch Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf | Patch Vendor Advisory |
Configurations
Configuration 1 (hide)
|
Configuration 2 (hide)
|
History
21 Nov 2024, 06:14
Type | Values Removed | Values Added |
---|---|---|
References | () https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf - Patch, Vendor Advisory | |
References | () https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf - Patch, Vendor Advisory |
Information
Published : 2021-09-14 11:15
Updated : 2024-11-21 06:14
NVD link : CVE-2021-37203
Mitre link : CVE-2021-37203
CVE.ORG link : CVE-2021-37203
JSON object : View
Products Affected
siemens
- nx_1980
- solid_edge
CWE
CWE-125
Out-of-bounds Read