{"id": "CVE-2021-37174", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 9.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "authentication": "SINGLE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 8.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}]}, "published": "2021-09-14T11:15:25.273", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf", "tags": ["Patch", "Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf", "tags": ["Patch", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-250"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices have a privilege escalation vulnerability, if exploited, an attacker could gain root user access."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en RUGGEDCOM ROX MX5000 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1400 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1500 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1501 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1510 (Todas las versiones anteriores a V2. 14.1), RUGGEDCOM ROX RX1511 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1512 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1524 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX1536 (Todas las versiones anteriores a V2.14.1), RUGGEDCOM ROX RX5000 (Todas las versiones anteriores a V2.14.1). Los dispositivos afectados presentan una vulnerabilidad de escalada de privilegios, si es explotado, un atacante podr\u00eda conseguir acceso de usuario root"}], "lastModified": "2024-11-21T06:14:47.580", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1400_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D5538013-C23A-4D6D-8756-8BE210EBEA53", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "12BD4008-DB6A-4749-A426-D2DE44819A9D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_mx5000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "183C516E-5BD4-4B50-841F-82AC3F68D12F", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "DAD1B18F-9C37-48CC-92E2-9C5E66B206CB"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1500_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6A64F21F-30C7-4164-A791-2AE72085EC8D", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3E79B422-C844-411C-AA49-CFD73D3C6E2D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1501_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9E7941A4-2B67-4B27-ACB2-E53449AD766F", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "53AAEC5C-06EE-4C58-A981-EBF5860CEF16"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1510_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "411252B0-9AE4-41F9-876C-A5863CFFA23C", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0751225A-6E9C-4281-93A4-A048920FF7C6"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1511_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "AF574446-EE25-4603-A831-E4766B5E234F", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "8C1E56ED-1E61-4B7E-8EC0-BB2AAD57EF7B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1512_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "942464AE-7E81-43D1-9996-27B7C87C26A8", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "41ADD701-AD49-46B2-A12E-219CCED32298"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1524_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CFEC6D28-3CD1-4786-8F83-DC9A64087879", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F8C70D90-E8FA-4343-9027-152A99D79C82"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1536_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2AAFB653-F651-4366-B4B4-4185EA89E31F", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C1775F3B-6F47-4134-8B4E-CF6337FF546C"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx5000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4E0625F9-DCD4-4DF6-9479-3DAE4BDB6976", "versionEndExcluding": "2.14.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "1E0E33F2-E89B-4008-BED2-CF2296801078"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "productcert@siemens.com"}