CVE-2021-35534

Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal database tables, could allow anybody with user credentials to bypass security controls that is enforced by the product. Consequently, exploitation may lead to unauthorized modifications on data/firmware, and/or to permanently disabling the product. This issue affects: Hitachi Energy Relion 670 Series 2.0 all revisions; 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.5. Hitachi Energy Relion 670/650 Series 2.1 all revisions. 2.2.0 all revisions; 2.2.4 all revisions; Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions; 2.2.5 versions prior to 2.2.5.2. Hitachi Energy Relion 650 1.0 all revisions. 1.1 all revisions; 1.2 all revisions; 1.3 versions prior to 1.3.0.8; Hitachi Energy GMS600 1.3.0; 1.3.0.1; 1.2.0. Hitachi Energy PWC600 1.0.1 version 1.0.1.4 and prior versions; 1.1.0 version 1.1.0.1 and prior versions.
Configurations

Configuration 1 (hide)

AND
OR cpe:2.3:o:hitachienergy:gms600_firmware:1.2.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:gms600_firmware:1.3.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:gms600_firmware:1.3.1.0:*:*:*:*:*:*:*
cpe:2.3:h:hitachienergy:gms600:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
OR cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_670_firmware:2.0.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_670_firmware:2.1.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.1:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.2:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.3:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.4:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.5:*:*:*:*:*:*:*
cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
OR cpe:2.3:o:hitachienergy:relion_650_firmware:1.0.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:1.1.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:1.2.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:1.3.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:2.1.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.4:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.5:*:*:*:*:*:*:*
cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
OR cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.5:*:*:*:*:*:*:*
cpe:2.3:h:hitachienergy:relion_sam600-io:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
OR cpe:2.3:o:hitachienergy:pwc600_firmware:1.0.1.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:pwc600_firmware:1.0.1.1:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:pwc600_firmware:1.0.1.3:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:pwc600_firmware:1.0.1.4:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:pwc600_firmware:1.1.0.0:*:*:*:*:*:*:*
cpe:2.3:o:hitachienergy:pwc600_firmware:1.1.0.1:*:*:*:*:*:*:*
cpe:2.3:h:hitachienergy:pwc600:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2021-11-18 17:15

Updated : 2024-02-28 18:48


NVD link : CVE-2021-35534

Mitre link : CVE-2021-35534

CVE.ORG link : CVE-2021-35534


JSON object : View

Products Affected

hitachienergy

  • pwc600_firmware
  • gms600
  • relion_670
  • pwc600
  • gms600_firmware
  • relion_650
  • relion_670_firmware
  • relion_650_firmware
  • relion_sam600-io_firmware
  • relion_sam600-io
CWE
CWE-269

Improper Privilege Management

CWE-274

Improper Handling of Insufficient Privileges