CVE-2021-33625

An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
Configurations

Configuration 1 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 2 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 3 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 4 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 5 (hide)

cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*

Configuration 6 (hide)

cpe:2.3:o:netapp:fas\/aff_bios:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:ruggedcom_ape1808:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc127e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:simatic_itp1000_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc277g_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc227g_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc327g_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc377g_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc427e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc477e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*

Configuration 17 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc477e_pro_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*

Configuration 18 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc627e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*

Configuration 19 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc647e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*

Configuration 20 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc677e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*

Configuration 21 (hide)

AND
cpe:2.3:o:siemens:simatic_ipc847e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*

Configuration 22 (hide)

AND
cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*

History

21 Nov 2024, 06:09

Type Values Removed Values Added
References () https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf - Third Party Advisory () https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf - Third Party Advisory
References () https://security.netapp.com/advisory/ntap-20220222-0004/ - Third Party Advisory () https://security.netapp.com/advisory/ntap-20220222-0004/ - Third Party Advisory
References () https://www.insyde.com/security-pledge - Vendor Advisory () https://www.insyde.com/security-pledge - Vendor Advisory
References () https://www.insyde.com/security-pledge/SA-2022014 - Vendor Advisory () https://www.insyde.com/security-pledge/SA-2022014 - Vendor Advisory

Information

Published : 2022-02-03 02:15

Updated : 2024-11-21 06:09


NVD link : CVE-2021-33625

Mitre link : CVE-2021-33625

CVE.ORG link : CVE-2021-33625


JSON object : View

Products Affected

siemens

  • simatic_ipc427e
  • simatic_ipc627e
  • simatic_ipc227g_firmware
  • simatic_ipc477e
  • simatic_field_pg_m6
  • simatic_ipc377g_firmware
  • simatic_field_pg_m5
  • simatic_ipc647e_firmware
  • simatic_ipc127e_firmware
  • simatic_field_pg_m6_firmware
  • simatic_itp1000_firmware
  • ruggedcom_ape1808
  • simatic_ipc627e_firmware
  • simatic_ipc377g
  • simatic_ipc847e_firmware
  • simatic_ipc477e_firmware
  • simatic_ipc277g
  • simatic_ipc277g_firmware
  • simatic_ipc477e_pro
  • simatic_field_pg_m5_firmware
  • simatic_ipc677e_firmware
  • simatic_ipc647e
  • simatic_ipc677e
  • simatic_ipc327g
  • ruggedcom_ape1808_firmware
  • simatic_ipc227g
  • simatic_ipc127e
  • simatic_ipc477e_pro_firmware
  • simatic_ipc427e_firmware
  • simatic_ipc847e
  • simatic_itp1000
  • simatic_ipc327g_firmware

netapp

  • fas\/aff_bios

insyde

  • insydeh2o
CWE
CWE-119

Improper Restriction of Operations within the Bounds of a Memory Buffer