CVE-2021-31885

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2021-11-09 12:15

Updated : 2024-02-28 18:48


NVD link : CVE-2021-31885

Mitre link : CVE-2021-31885

CVE.ORG link : CVE-2021-31885


JSON object : View

Products Affected

siemens

  • apogee_pxc_modular_firmware
  • talon_tc_modular_firmware
  • apogee_modular_building_controller_firmware
  • nucleus_readystart_v4
  • apogee_pxc_compact
  • nucleus_readystart_v3
  • capital_vstar
  • apogee_pxc_compact_firmware
  • talon_tc_modular
  • apogee_modular_equiment_controller_firmware
  • apogee_modular_equiment_controller
  • nucleus_source_code
  • apogee_modular_building_controller
  • talon_tc_compact
  • nucleus_net
  • apogee_pxc_modular
  • talon_tc_compact_firmware
CWE
CWE-805

Buffer Access with Incorrect Length Value