CVE-2021-25663

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:capital_vstar:-:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:*

Configuration 2 (hide)

cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:*

History

21 Nov 2024, 05:55

Type Values Removed Values Added
References () https://cert-portal.siemens.com/productcert/html/ssa-248289.html - () https://cert-portal.siemens.com/productcert/html/ssa-248289.html -
References () https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf - Vendor Advisory () https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf - Vendor Advisory
References () https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05 - Third Party Advisory, US Government Resource () https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05 - Third Party Advisory, US Government Resource

13 Feb 2024, 09:15

Type Values Removed Values Added
References
  • () https://cert-portal.siemens.com/productcert/html/ssa-248289.html -
Summary A vulnerability has been identified in Capital VSTAR (Versions including affected IPv6 stack), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values. A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.

Information

Published : 2021-04-22 21:15

Updated : 2024-11-21 05:55


NVD link : CVE-2021-25663

Mitre link : CVE-2021-25663

CVE.ORG link : CVE-2021-25663


JSON object : View

Products Affected

siemens

  • nucleus_readystart
  • nucleus_source_code
  • capital_vstar
  • nucleus_net
CWE
CWE-835

Loop with Unreachable Exit Condition ('Infinite Loop')