{"id": "CVE-2021-22772", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2021-07-21T15:15:15.117", "references": [{"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-05", "tags": ["Vendor Advisory"], "source": "cybersecurity@se.com"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-306"}]}, {"type": "Secondary", "source": "cybersecurity@se.com", "description": [{"lang": "en", "value": "CWE-306"}]}], "descriptions": [{"lang": "en", "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when authentication is bypassed."}, {"lang": "es", "value": "A CWE-306: Se presenta una vulnerabilidad de Falta de Autentificaci\u00f3n para una Funci\u00f3n Cr\u00edtica en Easergy T200 ((Modbus) SC2-04MOD-07000100 y anteriores), Easergy T200 ((IEC104) SC2-04IEC-07000100 y anteriores) y Easergy T200 ((DNP3) SC2-04DNP-07000102 y anteriores) que podr\u00eda causar una operaci\u00f3n no autorizada cuando es omitida la autenticaci\u00f3n"}], "lastModified": "2021-07-28T14:35:08.187", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:t200i_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2E9655C7-C2C9-444F-9947-35DF285BFADF", "versionEndIncluding": "sc2-04mod-07000100"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:t200i:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "9FAE4F40-8155-4B2B-9792-A26A05D7E95D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:t200i_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FC20FA4B-9261-4A8D-AC52-3BF8EE36CBC1", "versionEndIncluding": "sc2-04iec-07000100"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:t200i:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "9FAE4F40-8155-4B2B-9792-A26A05D7E95D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:t200i_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "06106386-3431-4F17-BD07-8DB75958F0D9", "versionEndIncluding": "sc2-04dnp-07000102"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:t200i:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "9FAE4F40-8155-4B2B-9792-A26A05D7E95D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:t200e_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C10F9475-BAAD-42EF-B40A-66C5A43247FE", "versionEndIncluding": "sc2-04mod-07000100"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:t200e:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BB10B0CE-A7B1-4314-9C44-BC6EA0130F03"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:t200e_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A8FED2E9-4F9A-46B1-A4D8-25AED9A8233F", "versionEndIncluding": "sc2-04iec-07000100"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:t200e:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BB10B0CE-A7B1-4314-9C44-BC6EA0130F03"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:t200e_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FCC668BF-FEA7-4331-A1BD-0D091E92A2FA", "versionEndIncluding": "sc2-04dnp-07000102"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:t200e:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BB10B0CE-A7B1-4314-9C44-BC6EA0130F03"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:t200p_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B9EDA52A-48AB-49F3-9E5B-13CC3BDDDB9A", "versionEndIncluding": "sc2-04mod-07000100"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:t200p:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "2E9591F3-1A7D-4727-BE81-836C49E9CE59"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:t200p_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BB389912-554D-4781-95E2-D2554F0CC5F9", "versionEndIncluding": "sc2-04iec-07000100"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:t200p:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "2E9591F3-1A7D-4727-BE81-836C49E9CE59"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:t200p_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D09BBBF5-312F-4CF6-88EA-50277AA98F2E", "versionEndIncluding": "sc2-04dnp-07000102"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:t200p:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "2E9591F3-1A7D-4727-BE81-836C49E9CE59"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cybersecurity@se.com"}