A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device
executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset.
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/html/ssa-783481.html | |
https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf | Vendor Advisory |
Configurations
Configuration 1 (hide)
AND |
|
History
21 Nov 2024, 05:17
Type | Values Removed | Values Added |
---|---|---|
References | () https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf - Vendor Advisory |
10 Sep 2024, 10:15
Type | Values Removed | Values Added |
---|---|---|
References |
|
|
Summary | (en) A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset. |
12 Dec 2023, 12:15
Type | Values Removed | Values Added |
---|---|---|
Summary | A vulnerability has been identified in LOGO! 12/24RCE (All versions), LOGO! 12/24RCEo (All versions), LOGO! 230RCE (All versions), LOGO! 230RCEo (All versions), LOGO! 24CE (All versions), LOGO! 24CEo (All versions), LOGO! 24RCE (All versions), LOGO! 24RCEo (All versions), SIPLUS LOGO! 12/24RCE (All versions), SIPLUS LOGO! 12/24RCEo (All versions), SIPLUS LOGO! 230RCE (All versions), SIPLUS LOGO! 230RCEo (All versions), SIPLUS LOGO! 24CE (All versions), SIPLUS LOGO! 24CEo (All versions), SIPLUS LOGO! 24RCE (All versions), SIPLUS LOGO! 24RCEo (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset. |
Information
Published : 2021-03-15 17:15
Updated : 2024-11-21 05:17
NVD link : CVE-2020-25236
Mitre link : CVE-2020-25236
CVE.ORG link : CVE-2020-25236
JSON object : View
Products Affected
siemens
- logo\!_8_bm
- logo\!_8_bm_firmware
CWE
CWE-755
Improper Handling of Exceptional Conditions