{"id": "CVE-2020-25180", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 4.3, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "MEDIUM", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 6.5, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 2.8}, {"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 5.3, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "REQUIRED", "attackComplexity": "HIGH", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 1.6}]}, "published": "2022-03-18T18:15:09.187", "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-04", "tags": ["Vendor Advisory"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131699", "tags": ["Permissions Required"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-280-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://www.xylem.com/siteassets/about-xylem/cybersecurity/advisories/xylem-multismart-rockwell-isagraf.pdf", "tags": ["Third Party Advisory"], "source": "ics-cert@hq.dhs.gov"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-798"}]}, {"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-321"}]}], "descriptions": [{"lang": "en", "value": "Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device."}, {"lang": "es", "value": "Rockwell Automation ISaGRAF Runtime versiones 4.x y 5.x, incluyen la funcionalidad setting a password que es requerida para ejecutar comandos privilegiados. El valor de la contrase\u00f1a que es pasada a ISaGRAF Runtime es el resultado de la encriptaci\u00f3n llevada a cabo con un valor de clave fijo usando el algoritmo de encriptaci\u00f3n diminuto (TEA) en una contrase\u00f1a introducida o guardada. Un atacante remoto, no autenticado, podr\u00eda pasar su propia contrase\u00f1a encriptada al ISaGRAF 5 Runtime, lo que podr\u00eda resultar en una divulgaci\u00f3n de informaci\u00f3n en el dispositivo"}], "lastModified": "2022-04-04T20:59:49.830", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:easergy_t300_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E07AFED6-47CC-4A19-80DB-C537F4F07736", "versionEndIncluding": "2.7.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:easergy_t300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "45E6C3FA-001D-449A-A512-327FA0C9AC5A"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:easergy_c5_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "01E1BC45-FFB3-4D5A-BA09-BA56A492E784", "versionEndExcluding": "1.1.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:easergy_c5:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A2EF5114-E9EB-47E1-A388-0963337906C6"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:micom_c264_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "17A5F6A2-32F6-4CDA-B2FE-EAA86B6BC43F", "versionEndExcluding": "d6.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:micom_c264:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A4F6A5C4-E0B2-44F2-823F-9E9C59E7B1F5"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.1:*:*:*:*:windows:*:*", "vulnerable": true, "matchCriteriaId": "716B1453-6203-4E7C-947D-71A031F79B3E"}, {"criteria": "cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.2:*:*:*:*:windows:*:*", "vulnerable": true, "matchCriteriaId": "05986825-76CD-486D-941A-E69A084F2A3E"}, {"criteria": "cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.1:*:*:*:*:windows:*:*", "vulnerable": true, "matchCriteriaId": "F59F968F-E480-4262-9754-BBC180E1AE24"}, {"criteria": "cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:linux:*:*", "vulnerable": true, "matchCriteriaId": "514C1283-E965-4543-991B-24FD5AA07D58"}, {"criteria": "cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:windows:*:*", "vulnerable": true, "matchCriteriaId": "E3FDEC1C-930B-4B8D-A67A-1D46E2069A9B"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:pacis_gtw:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "2240540D-73BB-47F1-A8CA-844DC6B00CE6"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:saitel_dp_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "AC5965EE-EB40-443A-BFDE-E97BD1C0F4E3", "versionEndIncluding": "11.06.21"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:saitel_dp:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "E6D73382-1957-4CC7-953F-D57C005D63B0"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:linux:*:*", "vulnerable": true, "matchCriteriaId": "6011641C-4319-4FC3-9EB4-F8537A2C50C9"}, {"criteria": "cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:windows:*:*", "vulnerable": true, "matchCriteriaId": "A08C5894-6894-44B7-809C-542732BDE84B"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:epas_gtw:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4034AC56-BEC6-49EA-9C42-6D0AE360B7E1"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:saitel_dr_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "47A24A85-B912-4A15-AB2E-BF2EE739686F", "versionEndIncluding": "11.06.12"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:saitel_dr:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "E65C2AD5-0079-47AA-82F3-F9335DCFA0AA"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:scd2200_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6D556CAB-DA72-4978-BB45-5B2834C03061", "versionEndIncluding": "10024"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:cp-3:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7C543522-AD89-48DD-90BB-47D686E93ADF"}, {"criteria": "cpe:2.3:h:schneider-electric:mc-31:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "53C778F7-64DA-4FD4-BB7F-2E5BB8BDB774"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:rockwellautomation:aadvance_controller:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "81F6F3FE-B508-4482-B832-992242F80D30", "versionEndIncluding": "1.40"}, {"criteria": "cpe:2.3:a:rockwellautomation:isagraf_free_runtime:*:*:*:*:*:isagraf6_workbench:*:*", "vulnerable": true, "matchCriteriaId": "6B1C6230-85E9-4053-90EB-715919960F80", "versionEndIncluding": "6.6.8"}, {"criteria": "cpe:2.3:a:rockwellautomation:isagraf_runtime:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7B3B8CEE-D6C8-44D9-B601-F862185A6075", "versionEndExcluding": "6.0", "versionStartIncluding": "5.0"}], "operator": "OR"}]}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micro810_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5798DD01-C49B-4DA9-9E83-2C875A345A1A"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micro810:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7CBC81B7-2559-46EB-A129-0456442C06D9"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micro820_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D9FCA425-ACD4-4F6F-97CF-3B05A1C003E8"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micro820:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7635A8EC-2D15-4BC6-938C-DC30AA21BEAB"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micro830_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9BFBB963-DD14-405D-B9ED-6277354A5A57"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micro830:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "8EE48F31-B3FE-463F-B366-05116E4093DE"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micro850_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8EEDFAA2-4E38-457E-9E50-802984D1C0E6"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micro850:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "B8BD0226-7434-4849-AD0D-35AB5A793F25"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micro870_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CAFD020B-28D9-4EC5-A282-4D42DC02A34C"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micro870:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "09DEF107-D1C4-456A-BB02-1731498568FD"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:xylem:multismart_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F64B0A94-A252-4052-A2C2-CD2374E3CCF2", "versionEndExcluding": "3.2.0"}], "operator": "OR"}]}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}