{"id": "CVE-2020-14441", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.8, "accessVector": "ADJACENT_NETWORK", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 6.5, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Secondary", "source": "cve@mitre.org", "cvssData": {"scope": "CHANGED", "version": "3.0", "baseScore": 9.6, "attackVector": "ADJACENT_NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 6.0, "exploitabilityScore": 2.8}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 8.8, "attackVector": "ADJACENT_NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}]}, "published": "2020-06-18T17:15:13.233", "references": [{"url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071", "tags": ["Vendor Advisory"], "source": "cve@mitre.org"}, {"url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-77"}]}], "descriptions": [{"lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25."}, {"lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25"}], "lastModified": "2024-11-21T05:03:17.100", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cve@mitre.org"}