CVE-2019-10964

In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump – All versions, MiniMed Paradigm 511 pump – All versions, MiniMed Paradigm 512/712 pumps – All versions, MiniMed Paradigm 712E pump–All versions, MiniMed Paradigm 515/715 pumps–All versions, MiniMed Paradigm 522/722 pumps – All versions,MiniMed Paradigm 522K/722K pumps – All versions, MiniMed Paradigm 523/723 pumps – Software versions 2.4A or lower, MiniMed Paradigm 523K/723K pumps – Software, versions 2.4A or lower, MiniMed Paradigm Veo 554/754 pumps – Software versions 2.6A or lower, MiniMed Paradigm Veo 554CM and 754CM models only – Software versions 2.7A or lower, the affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
References
Link Resource
http://www.securityfocus.com/bid/108926 Third Party Advisory VDB Entry
https://www.us-cert.gov/ics/advisories/icsma-19-178-01 Third Party Advisory US Government Resource
http://www.securityfocus.com/bid/108926 Third Party Advisory VDB Entry
https://www.us-cert.gov/ics/advisories/icsma-19-178-01 Third Party Advisory US Government Resource
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:medtronic:minimed_508_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_508:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_511_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_511:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_512_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_512:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_712_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_712:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_712e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_712e:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_515_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_515:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_715_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_715:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_522_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_522:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_722_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_722:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_522k_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_522k:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_722k_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_722k:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_523_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_523:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_723_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_723:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_523k_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_523k:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_723k_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_723k:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_veo_554_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_veo_554:-:*:*:*:*:*:*:*

Configuration 17 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_veo_754_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_veo_754:-:*:*:*:*:*:*:*

Configuration 18 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_veo_554cm_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_veo_554cm:*:*:*:*:*:*:*:*

Configuration 19 (hide)

AND
cpe:2.3:o:medtronic:minimed_paradigm_veo_754cm_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:medtronic:minimed_paradigm_veo_754cm:-:*:*:*:*:*:*:*

History

21 Nov 2024, 04:20

Type Values Removed Values Added
References () http://www.securityfocus.com/bid/108926 - Third Party Advisory, VDB Entry () http://www.securityfocus.com/bid/108926 - Third Party Advisory, VDB Entry
References () https://www.us-cert.gov/ics/advisories/icsma-19-178-01 - Third Party Advisory, US Government Resource () https://www.us-cert.gov/ics/advisories/icsma-19-178-01 - Third Party Advisory, US Government Resource

Information

Published : 2019-06-28 21:15

Updated : 2024-11-21 04:20


NVD link : CVE-2019-10964

Mitre link : CVE-2019-10964

CVE.ORG link : CVE-2019-10964


JSON object : View

Products Affected

medtronic

  • minimed_paradigm_712e_firmware
  • minimed_paradigm_511_firmware
  • minimed_paradigm_715
  • minimed_paradigm_715_firmware
  • minimed_paradigm_723_firmware
  • minimed_paradigm_515
  • minimed_paradigm_722
  • minimed_paradigm_522_firmware
  • minimed_paradigm_723k_firmware
  • minimed_paradigm_523k_firmware
  • minimed_paradigm_512_firmware
  • minimed_paradigm_712
  • minimed_paradigm_522k
  • minimed_508_firmware
  • minimed_paradigm_512
  • minimed_paradigm_veo_554cm_firmware
  • minimed_paradigm_723
  • minimed_paradigm_veo_554cm
  • minimed_paradigm_511
  • minimed_paradigm_523
  • minimed_paradigm_veo_554_firmware
  • minimed_paradigm_522k_firmware
  • minimed_paradigm_515_firmware
  • minimed_paradigm_522
  • minimed_paradigm_veo_754cm_firmware
  • minimed_paradigm_veo_754cm
  • minimed_paradigm_722_firmware
  • minimed_paradigm_veo_754
  • minimed_paradigm_523k
  • minimed_paradigm_712_firmware
  • minimed_508
  • minimed_paradigm_712e
  • minimed_paradigm_veo_754_firmware
  • minimed_paradigm_722k
  • minimed_paradigm_722k_firmware
  • minimed_paradigm_523_firmware
  • minimed_paradigm_723k
  • minimed_paradigm_veo_554
CWE
CWE-287

Improper Authentication

CWE-863

Incorrect Authorization