CVE-2019-10917

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_pcs_7:9.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):13.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):15.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*

History

21 Nov 2024, 04:20

Type Values Removed Values Added
References () https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf - Vendor Advisory () https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf - Vendor Advisory
References () https://www.us-cert.gov/ics/advisories/ICSA-19-134-08 - Third Party Advisory, US Government Resource () https://www.us-cert.gov/ics/advisories/ICSA-19-134-08 - Third Party Advisory, US Government Resource

Information

Published : 2019-05-14 20:29

Updated : 2024-11-21 04:20


NVD link : CVE-2019-10917

Mitre link : CVE-2019-10917

CVE.ORG link : CVE-2019-10917


JSON object : View

Products Affected

siemens

  • simatic_wincc_\(tia_portal\)
  • simatic_wincc_runtime_professional
  • simatic_pcs_7
  • simatic_wincc
CWE
CWE-248

Uncaught Exception

CWE-755

Improper Handling of Exceptional Conditions