CVE-2018-9076

For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, when changing the name of a share, an attacker can craft a command injection payload using backtick "``" characters in the name parameter. As a result, arbitrary commands may be executed as the root user. The attack requires a value __c and iomega parameter.
References
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:lenovo:lenovoemc_firmware:*:*:*:*:*:*:*:*
OR cpe:2.3:h:lenovo:iomega_ez_media_\&_backup_center:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_ix2:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_ix2-dl:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_ix4-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px12-400r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px12-450r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px2-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px4-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px4-300r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:iomega_storcenter_px6-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovo_ez_media_\&_backup_center:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovo_ix2:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovo_ix4-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovoemc_px12-400r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovoemc_px12-450r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovoemc_px2-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovoemc_px4-300d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovoemc_px4-300r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovoemc_px4-400d:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovoemc_px4-400r:-:*:*:*:*:*:*:*
cpe:2.3:h:lenovo:lenovoemc_px6-300d:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2018-09-28 20:29

Updated : 2024-02-28 16:48


NVD link : CVE-2018-9076

Mitre link : CVE-2018-9076

CVE.ORG link : CVE-2018-9076


JSON object : View

Products Affected

lenovo

  • iomega_storcenter_ix2-dl
  • iomega_storcenter_px12-450r
  • lenovo_ez_media_\&_backup_center
  • lenovoemc_px4-400d
  • iomega_storcenter_px12-400r
  • lenovo_ix4-300d
  • lenovoemc_px6-300d
  • iomega_ez_media_\&_backup_center
  • lenovoemc_px4-400r
  • lenovoemc_px4-300r
  • lenovoemc_px4-300d
  • lenovoemc_px12-400r
  • lenovo_ix2
  • iomega_storcenter_ix4-300d
  • iomega_storcenter_ix2
  • lenovoemc_px2-300d
  • lenovoemc_firmware
  • iomega_storcenter_px4-300d
  • iomega_storcenter_px2-300d
  • lenovoemc_px12-450r
  • iomega_storcenter_px4-300r
  • iomega_storcenter_px6-300d
CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')