{"id": "CVE-2018-13814", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 6.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}]}, "published": "2018-12-13T16:29:00.350", "references": [{"url": "http://www.securityfocus.com/bid/105931", "tags": ["Third Party Advisory", "VDB Entry"], "source": "productcert@siemens.com"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", "tags": ["Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "http://www.securityfocus.com/bid/105931", "tags": ["Third Party Advisory", "VDB Entry"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-113"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-20"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" 15\" (todas las versiones anteriores a V14 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Advanced (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) (todas las versiones anteriores a V14) y SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (todas las versiones). El servidor web integrado (puerto 80/tcp y puerto 443/tcp) de los dispositivos afectados podr\u00eda permitir que un atacante inyecte cabeceras HTTP. Un atacante debe enga\u00f1ar a un usuario v\u00e1lido autenticado en el dispositivo para que haga clic en un enlace malicioso y explote esta vulnerabilidad. En el momento de la publicaci\u00f3n del aviso, no se conoce ninguna explotaci\u00f3n p\u00fablica de la vulnerabilidad de seguridad."}], "lastModified": "2024-11-21T03:48:07.560", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1E4E5DE2-34BF-4B0E-9C53-FF53255DEA72", "versionEndExcluding": "14.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8ED4BD65-A2BC-45DB-8465-1A5846916522", "versionEndExcluding": "14.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A37DC20C-7FE9-42B0-BD92-01FD2F40D2A9", "versionEndExcluding": "14.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B75E3C61-A501-4B4F-98E8-E0DA53C7CD78", "versionEndExcluding": "14.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C2A9006B-1C42-4E97-9FDA-225974F5FD16", "versionEndExcluding": "14.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "86A4CFE5-471A-4710-8712-66B0ECDC8214", "versionEndExcluding": "14.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0A449791-25A0-46A0-A022-EACCAE506189", "versionEndExcluding": "14.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "09ACCC3D-B2C3-4920-9A2D-EF4D65C60505", "versionEndExcluding": "14.0"}, {"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*", "vulnerable": true, "matchCriteriaId": "F4E97D44-F06E-411E-ABAA-ACFB8AABEFA3", "versionEndExcluding": "14.0"}, {"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*", "vulnerable": true, "matchCriteriaId": "3876E5D8-AA56-4262-B245-CD5915AF4CAD", "versionEndExcluding": "14.0"}], "operator": "OR"}]}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "983886F3-5B11-4AC3-A4D9-C2816F9A37DF"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "EE8F082D-04C4-4A3E-B3D1-6C2914C2917E"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A2271FBE-FF50-4614-A4A5-BBAB800F5FBD"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "68C30B3C-90EF-4244-9235-D87A421850DC"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "217870AC-9EB0-4BDE-A2E2-381055B8E69C"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A17F4CDF-5367-4343-AA1E-0C452495E598"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "productcert@siemens.com"}