{"id": "CVE-2018-0343", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 6.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "authentication": "SINGLE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": true, "impactScore": 6.4, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}]}, "published": "2018-07-18T23:29:00.290", "references": [{"url": "http://www.securityfocus.com/bid/104861", "tags": ["Third Party Advisory", "VDB Entry"], "source": "ykramarz@cisco.com"}, {"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180718-sd-wan-code-ex", "tags": ["Vendor Advisory"], "source": "ykramarz@cisco.com"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-269"}]}, {"type": "Secondary", "source": "ykramarz@cisco.com", "description": [{"lang": "en", "value": "CWE-284"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability in the configuration and management service of the Cisco SD-WAN Solution could allow an authenticated, remote attacker to execute arbitrary code with vmanage user privileges or cause a denial of service (DoS) condition on an affected system. The vulnerability is due to insufficient access restrictions to the HTTP management interface of the affected solution. An attacker could exploit this vulnerability by sending a malicious HTTP request to the affected management service through an authenticated device. A successful exploit could allow the attacker to execute arbitrary code with vmanage user privileges or stop HTTP services on an affected system. This vulnerability affects the following Cisco products if they are running a release of the Cisco SD-WAN Solution prior to Release 18.3.0: vBond Orchestrator Software, vEdge 100 Series Routers, vEdge 1000 Series Routers, vEdge 2000 Series Routers, vEdge 5000 Series Routers, vEdge Cloud Router Platform, vManage Network Management Software, vSmart Controller Software. Cisco Bug IDs: CSCvi69976."}, {"lang": "es", "value": "Una vulnerabilidad en el servicio de configuraci\u00f3n y gesti\u00f3n de Cisco SD-WAN Solution podr\u00eda permitir que un atacante remoto autenticado ejecute c\u00f3digo arbitrario con privilegios de usuario vmanage o provoque una condici\u00f3n de denegaci\u00f3n de servicio (DoS) en un sistema afectado. La vulnerabilidad se debe a las restricciones de acceso insuficientes en la interfaz de gesti\u00f3n HTTP de la soluci\u00f3n afectada. Un atacante podr\u00eda explotar esta vulnerabilidad enviando una petici\u00f3n HTTP maliciosa al servicio de gesti\u00f3n afectado mediante un dispositivo autenticado. Su explotaci\u00f3n con \u00e9xito podr\u00eda permitir que el atacante ejecute c\u00f3digo arbitrario con privilegios de usuario vmanage o detenga los servicios HTTP en un sistema afectado. Esta vulnerabilidad afecta a los siguientes productos Cisco si est\u00e1n ejecutando una versi\u00f3n de Cisco SD-WAN Solution anterior a la 18.3.0: vBond Orchestrator Software, vEdge 100 Series Routers, vEdge 1000 Series Routers, vEdge 2000 Series Routers, vEdge 5000 Series Routers, vEdge Cloud Router Platform, vManage Network Management Software y vSmart Controller Software. Cisco Bug IDs: CSCvi69976."}], "lastModified": "2019-10-09T23:31:49.317", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:cisco:vbond_orchestrator:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BA648664-0734-4D02-8944-CA4DF4D756D6"}, {"criteria": "cpe:2.3:a:cisco:vedge-plus:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8828CED0-5B61-4BC9-B222-2295507E5FB7"}, {"criteria": "cpe:2.3:a:cisco:vedge-pro:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "937B8016-77E1-4F8C-8701-6AFFE36F6A49"}, {"criteria": "cpe:2.3:a:cisco:vmanage_network_management:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DDF9528B-1D1E-4CF2-ABA8-D01CC6F4A8BD"}, {"criteria": "cpe:2.3:a:cisco:vsmart_controller:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2F16884C-A2EE-4867-8806-6418E000078C"}], "operator": "OR"}]}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge-100_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "07BDB466-E5FC-40FF-8400-836551AD4AE5", "versionEndExcluding": "18.3.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge-100:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5D71E4AF-6E91-4493-A591-4D056D0E59C1"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge_100b_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "493ED5A7-3F08-4C2B-8259-F945088C42C4", "versionEndExcluding": "18.3.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge_100b:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0811E0B5-889E-451E-B754-A8FEE32BDFA2"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge_100m_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7A89574B-5FA1-45D2-92F5-E6AE60B21AAC", "versionEndExcluding": "18.3.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge_100m:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "36973815-F46D-4ADA-B9DF-BCB70AC60BD3"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge_100wm_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A124EBDB-1E4D-44FF-8647-342ACB7FC536", "versionEndExcluding": "18.3.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge_100wm:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "061A302C-8D35-4E80-93DA-916DA7E90C06"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge-1000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F33875D3-8A95-4201-B385-FA63CCDBE103", "versionEndExcluding": "18.3.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge-1000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F718A859-BCDB-4DD0-819D-60ABE710F0A9"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge-2000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6D486E57-9E41-4744-AB0C-56B706B6989C", "versionEndExcluding": "18.3.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge-2000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "52EEF288-492C-4CE6-A082-631005C5E711"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:cisco:vedge-5000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C78995CF-3005-496D-A168-F9EEF09EEF44", "versionEndExcluding": "18.3.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:cisco:vedge-5000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C0C5E2C9-7D4B-405C-93DD-33DF265131E2"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "ykramarz@cisco.com"}