A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
References
Link | Resource |
---|---|
http://www.securityfocus.com/bid/97254 | Third Party Advisory VDB Entry |
https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02 | Third Party Advisory US Government Resource |
Configurations
Configuration 1 (hide)
AND |
|
Configuration 2 (hide)
AND |
|
Configuration 3 (hide)
AND |
|
History
No history.
Information
Published : 2017-06-30 03:29
Updated : 2024-02-28 16:04
NVD link : CVE-2017-6030
Mitre link : CVE-2017-6030
CVE.ORG link : CVE-2017-6030
JSON object : View
Products Affected
schneider-electric
- modicon_m251_firmware
- modicon_m241_firmware
- modicon_m221
- modicon_m221_firmware
- modicon_m251
- modicon_m241